2010Physical Testing and Chemical AnalysisRequires access

HG-AFS Determination of Trace Amounts of Cadmium in Environmental Water

Sun Xian-rong

Open publisher page 0 citations

Abstract

HG-AFS was applied to the determination of trace amounts of cadmium in environmental water.It was found that in 0.12 mol·L-1 HCl solution,cadmium(Ⅱ) was reacted with potassium borohydride solution(30 g·L-1) to form cadmium hydride and determined by AFS.Cobalt(Ⅱ) attaining to mass concentration of 1 mg·L-1 was added to the test solution to enhance the intensity of fluorescence signal,and 10 g·L-1 thiourea solution was added as complexing agent.Linear relationship between values of fluorescence intensity and mass concentration of cadmium(Ⅱ) was obtained in the range within 6.0 μg·L-1 with its detection limit(3s/k) of 0.18 μg·L-1.The proposed method was used in the analysis of a water sample,on the base of which recovery was tested by standard addition method,giving results of average recovery of 96.3% and 101.7%.

About this research paper

What this paper is about

HG-AFS was applied to the determination of trace amounts of cadmium in environmental water.It was found that in 0.12 mol·L-1 HCl solution,cadmium(Ⅱ) was reacted with potassium borohydride solution(30 g·L-1) to form cadmium hydride and determined by AFS.Cobalt(Ⅱ) attaining to mass concentration of 1 mg·L-1 was added to the test solution to enhance the intensity of fluorescence signal,and 10 g·L-1 thiourea solution was added as complexing agent.Linear relationship between values of fluorescence intensity and mass concentration of cadmium(Ⅱ) was obtained in the range within 6.0 μg·L-1 with its detection limit(3s/k) of 0.18 μg·L-1.The proposed method was used in the analysis of a water sample,on the base of which recovery was tested by standard addition method,giving results of average recovery of 96.3% and 101.7%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

HG-AFS was applied to the determination of trace amounts of cadmium in environmental water.It was found that in 0.12 mol·L-1 HCl solution,cadmium(Ⅱ) was reacted with potassium borohydride solution(30 g·L-1) to form cadmium hydride and determined by AFS.Cobalt(Ⅱ) attaining to mass concentration of 1 mg·L-1 was added to the test solution to enhance the intensity of fluorescence signal,and 10 g·L-1 thiourea solution was added as complexing agent.Linear relationship between values of fluorescence intensity and mass concentration of cadmium(Ⅱ) was obtained in the range within 6.0 μg·L-1 with its detection limit(3s/k) of 0.18 μg·L-1.The proposed method was used in the analysis of a water sample,on the base of which recovery was tested by standard addition method,giving results of average recovery of 96.3% and 101.7%.

Key concepts: Cadmium, Chemistry, Thiourea, Detection limit, Trace Amounts, Mass concentration (chemistry), Cobalt, Fluorescence

Related papers

Back to paper searchBrowse research topicsOriginal source
HG-AFS Determination of Trace Amounts of Cadmium in Environmental Water — Research Paper | ScholarLens