2011Coal science and technologyRequires access

Study on Fluidization Characteristics of Air Heavy Medium Pulsed Fluidized Bed

Shao Ming

Open publisher page 0 citations

Abstract

In order to study the fluidized effect of the pulsed fluidized bed,a comparison experiment was conducted on the fluidized characteristics of the pulsed fluidized bed and the conventional fluidized bed under the conditions of the different pulsed air parameters and the analysis was conducted on the fluidized curves,the bed layer pressure drop of the fluidized bed and the density fluctuations at the center of the fluidized bed individually.The results showed that when the pulsed fluidized bed was in critical fluidization status,the pressure drop variation of the fluidized bed was stable and the fluidized curve could not appear a raised peak.The middle bed layer pressure drop fluctuations of the pulsed fluidized bed was obviously lower than the conventional fluidized bed and the stability of the bed density would be high.At the same fluidized number,the pulsed fluidized bed would have much lower bed density.

About this research paper

What this paper is about

In order to study the fluidized effect of the pulsed fluidized bed,a comparison experiment was conducted on the fluidized characteristics of the pulsed fluidized bed and the conventional fluidized bed under the conditions of the different pulsed air parameters and the analysis was conducted on the fluidized curves,the bed layer pressure drop of the fluidized bed and the density fluctuations at the center of the fluidized bed individually.The results showed that when the pulsed fluidized bed was in critical fluidization status,the pressure drop variation of the fluidized bed was stable and the fluidized curve could not appear a raised peak.The middle bed layer pressure drop fluctuations of the pulsed fluidized bed was obviously lower than the conventional fluidized bed and the stability of the bed density would be high.At the same fluidized number,the pulsed fluidized bed would have much lower bed density.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to study the fluidized effect of the pulsed fluidized bed,a comparison experiment was conducted on the fluidized characteristics of the pulsed fluidized bed and the conventional fluidized bed under the conditions of the different pulsed air parameters and the analysis was conducted on the fluidized curves,the bed layer pressure drop of the fluidized bed and the density fluctuations at the center of the fluidized bed individually.The results showed that when the pulsed fluidized bed was in critical fluidization status,the pressure drop variation of the fluidized bed was stable and the fluidized curve could not appear a raised peak.The middle bed layer pressure drop fluctuations of the pulsed fluidized bed was obviously lower than the conventional fluidized bed and the stability of the bed density would be high.At the same fluidized number,the pulsed fluidized bed would have much lower bed density.

Key concepts: Fluidized bed, Fluidization, Pressure drop, Drop (telecommunication), Materials science, Mechanics, Waste management, Electrical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Fluidization Characteristics of Air Heavy Medium Pulsed Fluidized Bed — Research Paper | ScholarLens