2013The Chinese Journal of Cardiac Pacing and ElectrophysiologyRequires access

Influence of ventricular intrinsic preference algorithm on the percentage of right ventricular pacing and heart function

Cai Zhen-ron

Open publisher page 0 citations

Abstract

Objective To investigate the impacts of ventricular intrinsic preference( VIP) algorithm on percentage of right ventricular pacing and heart function. Method Patients received permanent cardiac pacemaker for bradyarrhythmias were enrolled. Atrial leads were placed at right atricular appendage,ventricular leads were placed at right ventricuIar apex. The subjects were divided into experimental group and control group according to the functiong of VIP switched on or off. the concentration of brain natriuretic peptide( BNP). Left atrial diameter( LAD),left ventricular ejection fracetion( LVEF),left ventricular end diastolic diameter( LVEDD) were measured before operation and 12 months after implanting. The percentage of right ventricuIar pacing,the echocardiography parameters,the concentration of BNP and the distance of 6-minutes walking test at implantation and after implantation were compared respectively. Result A total of 62 patients were divided into experimental group( n = 30) and control group( n = 32). At 12 months after operation,the percentage of right ventricular pacing in experimental group decreased signifcantly compared with the control group[( 21. 43% ± 8. 57%) vs( 55. 26% ± 12. 36%),P 0. 001],LAD and LVEDD in control group were significantly larger,LVEF and the distance of 6-minutes walking test in control group were significantly lower( P 0. 05),the concentration of BNP in control group was higher than that in experimental group( P 0. 05). Conclusion VIP algorithm can effectively reduce the percentage of ventricular pacing,and protect heart function.[Chinese Journal of Cardiac Pacing and Electrophysiology,2014,28( 1) : 21-23]

About this research paper

What this paper is about

Objective To investigate the impacts of ventricular intrinsic preference( VIP) algorithm on percentage of right ventricular pacing and heart function. Method Patients received permanent cardiac pacemaker for bradyarrhythmias were enrolled. Atrial leads were placed at right atricular appendage,ventricular leads were placed at right ventricuIar apex. The subjects were divided into experimental group and control group according to the functiong of VIP switched on or off. the concentration of brain natriuretic peptide( BNP). Left atrial diameter( LAD),left ventricular ejection fracetion( LVEF),left ventricular end diastolic diameter( LVEDD) were measured before operation and 12 months after implanting. The percentage of right ventricuIar pacing,the echocardiography parameters,the concentration of BNP and the distance of 6-minutes walking test at implantation and after implantation were compared respectively. Result A total of 62 patients were divided into experimental group( n = 30) and control group( n = 32). At 12 months after operation,the percentage of right ventricular pacing in experimental group decreased signifcantly compared with the control group[( 21. 43% ± 8. 57%) vs( 55. 26% ± 12. 36%),P 0. 001],LAD and LVEDD in control group were significantly larger,LVEF and the distance of 6-minutes walking test in control group were significantly lower( P 0. 05),the concentration of BNP in control group was higher than that in experimental group( P 0. 05). Conclusion VIP algorithm can effectively reduce the percentage of ventricular pacing,and protect heart function.[Chinese Journal of Cardiac Pacing and Electrophysiology,2014,28( 1) : 21-23]

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the impacts of ventricular intrinsic preference( VIP) algorithm on percentage of right ventricular pacing and heart function. Method Patients received permanent cardiac pacemaker for bradyarrhythmias were enrolled. Atrial leads were placed at right atricular appendage,ventricular leads were placed at right ventricuIar apex. The subjects were divided into experimental group and control group according to the functiong of VIP switched on or off. the concentration of brain natriuretic peptide( BNP). Left atrial diameter( LAD),left ventricular ejection fracetion( LVEF),left ventricular end diastolic diameter( LVEDD) were measured before operation and 12 months after implanting. The percentage of right ventricuIar pacing,the echocardiography parameters,the concentration of BNP and the distance of 6-minutes walking test at implantation and after implantation were compared respectively. Result A total of 62 patients were divided into experimental group( n = 30) and control group( n = 32). At 12 months after operation,the percentage of right ventricular pacing in experimental group decreased signifcantly compared with the control group[( 21. 43% ± 8. 57%) vs( 55. 26% ± 12. 36%),P 0. 001],LAD and LVEDD in control group were significantly larger,LVEF and the distance of 6-minutes walking test in control group were significantly lower( P 0. 05),the concentration of BNP in control group was higher than that in experimental group( P 0. 05). Conclusion VIP algorithm can effectively reduce the percentage of ventricular pacing,and protect heart function.[Chinese Journal of Cardiac Pacing and Electrophysiology,2014,28( 1) : 21-23]

Key concepts: Medicine, Ejection fraction, Cardiology, Internal medicine, Ventricular pacing, Cardiac function curve, Brain natriuretic peptide, Ventricular function

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of ventricular intrinsic preference algorithm on the percentage of right ventricular pacing and heart function — Research Paper | ScholarLens