2007Physical Testing and Chemical AnalysisRequires access

STRESS CORROSION FAILURE ANALYSIS OF THE FASTENING BOLT AT HEAT EXCHANGER

You Xiang-qun

Open publisher page 0 citations

Abstract

The failure analysis of the bolts was made by macrostructure,chemical composieion,microstructure,fractography and EDS analysis.The results show that the stress corrosion,which is due to the interactions between the stresses and corrosion media,make the bolts fracture.All of the fastening bolts fracture after used two years,as the bolts was long-term immcrsed in oil which contains the H_2S.In addition,inproper material compositions,hardness,and microstructure also result in the fracture of the bolts.

About this research paper

What this paper is about

The failure analysis of the bolts was made by macrostructure,chemical composieion,microstructure,fractography and EDS analysis.The results show that the stress corrosion,which is due to the interactions between the stresses and corrosion media,make the bolts fracture.All of the fastening bolts fracture after used two years,as the bolts was long-term immcrsed in oil which contains the H_2S.In addition,inproper material compositions,hardness,and microstructure also result in the fracture of the bolts.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The failure analysis of the bolts was made by macrostructure,chemical composieion,microstructure,fractography and EDS analysis.The results show that the stress corrosion,which is due to the interactions between the stresses and corrosion media,make the bolts fracture.All of the fastening bolts fracture after used two years,as the bolts was long-term immcrsed in oil which contains the H_2S.In addition,inproper material compositions,hardness,and microstructure also result in the fracture of the bolts.

Key concepts: Fractography, Materials science, Microstructure, Corrosion, Fracture (geology), Stress (linguistics), Metallurgy, Composite material