2016IEEE Transactions on Nuclear ScienceRequires access

Thermal Neutron Filter Design for the Neutron Radiography Facility at the LVR-15 Reactor

Jaroslav Šoltés, L. Viererbl, Z. Lahodová, Michal Koleška, M. Vinš

Open publisher page 12 citations

Abstract

In the year 2011, a research project has started focus on building of a neutron radiography facility at the LVR-15 research reactor in Rez, Czech Republic. One of the unused horizontal channels was chosen to be adapted for this purpose. However, the original beam parameters having a high presence on fast neutrons which may damage the neutron detector, and gamma radiation which causes undesired background were unsuitable. The need for an intensive thermal neutron beam with a very low fast neutron ratio led to the decision of installing a thermal neutron filter into the channel tube. As the channel layout is very spatial limiting, a simple solution had to be chosen. Usually large single-crystal ingots of proper material parameters can be used as filters. Single-crystal silicon was chosen as the preferred filter material for its availability in sufficient dimensions and low production costs. Additionally to its ability to significantly reduce the ratio of fast neutrons in the beam, if the filter dimensions are large enough, it provides shielding against the reactor gamma radiation. For the calculation of the required beam dimensions the Monte-Carlo MCNP transport code was used. However, as the code does not include the neutron cross-section libraries for thermal neutron scattering on crystalline structures, the original silicon cross-section libraries had been manually modified using an approximated relation based on thermal neutron scattering theory. Carrying out a series of calculations the filter thickness of 1 m proved good for gaining a beam with desired parameters and a low gamma background. After mounting the filter inside the channel several measurements of the neutron field were realized at the beam exit. The results have justified the calculated values. After the successful filter installing and a series of measurements, first test neutron radiography attempts with chosen samples could been carried out.

About this research paper

What this paper is about

In the year 2011, a research project has started focus on building of a neutron radiography facility at the LVR-15 research reactor in Rez, Czech Republic. One of the unused horizontal channels was chosen to be adapted for this purpose. However, the original beam parameters having a high presence on fast neutrons which may damage the neutron detector, and gamma radiation which causes undesired background were unsuitable. The need for an intensive thermal neutron beam with a very low fast neutron ratio led to the decision of installing a thermal neutron filter into the channel tube. As the channel layout is very spatial limiting, a simple solution had to be chosen. Usually large single-crystal ingots of proper material parameters can be used as filters. Single-crystal silicon was chosen as the preferred filter material for its availability in sufficient dimensions and low production costs. Additionally to its ability to significantly reduce the ratio of fast neutrons in the beam, if the filter dimensions are large enough, it provides shielding against the reactor gamma radiation. For the calculation of the required beam dimensions the Monte-Carlo MCNP transport code was used. However, as the code does not include the neutron cross-section libraries for thermal neutron scattering on crystalline structures, the original silicon cross-section libraries had been manually modified using an approximated relation based on thermal neutron scattering theory. Carrying out a series of calculations the filter thickness of 1 m proved good for gaining a beam with desired parameters and a low gamma background. After mounting the filter inside the channel several measurements of the neutron field were realized at the beam exit. The results have justified the calculated values. After the successful filter installing and a series of measurements, first test neutron radiography attempts with chosen samples could been carried out.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the year 2011, a research project has started focus on building of a neutron radiography facility at the LVR-15 research reactor in Rez, Czech Republic. One of the unused horizontal channels was chosen to be adapted for this purpose. However, the original beam parameters having a high presence on fast neutrons which may damage the neutron detector, and gamma radiation which causes undesired background were unsuitable. The need for an intensive thermal neutron beam with a very low fast neutron ratio led to the decision of installing a thermal neutron filter into the channel tube. As the channel layout is very spatial limiting, a simple solution had to be chosen. Usually large single-crystal ingots of proper material parameters can be used as filters. Single-crystal silicon was chosen as the preferred filter material for its availability in sufficient dimensions and low production costs. Additionally to its ability to significantly reduce the ratio of fast neutrons in the beam, if the filter dimensions are large enough, it provides shielding against the reactor gamma radiation. For the calculation of the required beam dimensions the Monte-Carlo MCNP transport code was used. However, as the code does not include the neutron cross-section libraries for thermal neutron scattering on crystalline structures, the original silicon cross-section libraries had been manually modified using an approximated relation based on thermal neutron scattering theory. Carrying out a series of calculations the filter thickness of 1 m proved good for gaining a beam with desired parameters and a low gamma background. After mounting the filter inside the channel several measurements of the neutron field were realized at the beam exit. The results have justified the calculated values. After the successful filter installing and a series of measurements, first test neutron radiography attempts with chosen samples could been carried out.

Key concepts: Neutron imaging, Neutron, Nuclear engineering, Nuclear physics, Neutron temperature, Physics, Materials science, Medical physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Thermal Neutron Filter Design for the Neutron Radiography Facility at the LVR-15 Reactor — Research Paper | ScholarLens