2012cIRcle (University of British Columbia)Open access

Gas scintillation counters

George Beer

Open full text 0 citations

Abstract

Construction details of a 5" diameter 1.7 litre gas scintillation counter are given. The behaviour of the counter when containing He⁴ gas and a mixture of He⁴ and 10% Xe at various total pressures has been investigated. Two 5" photomultiplier tubes and a variety of different gas purifiers were tested in an attempt to obtain the best possible resolution. The pulse height was found to depend sensitively on the purification procedure adopted. A resolution of 10% for the Po²¹⁰ α-peak has been attained in two different chambers containing He⁴ plus 10% Xe. The voltage pulses rose in ≤300 nsec. Intense irradiation of a counter with 6 Mev x-rays caused only a slight increase in the maximum noise level already present from the photomultiplier tube. The behaviour of the counter as a fast neutron detector has been investigated using an uncollimated beam of 4.1 Mev neutrons. Pulses from recoiling protons and C¹² nuclei were observed as well as the He⁴ recoils.

About this research paper

What this paper is about

Construction details of a 5" diameter 1.7 litre gas scintillation counter are given. The behaviour of the counter when containing He⁴ gas and a mixture of He⁴ and 10% Xe at various total pressures has been investigated. Two 5" photomultiplier tubes and a variety of different gas purifiers were tested in an attempt to obtain the best possible resolution. The pulse height was found to depend sensitively on the purification procedure adopted. A resolution of 10% for the Po²¹⁰ α-peak has been attained in two different chambers containing He⁴ plus 10% Xe. The voltage pulses rose in ≤300 nsec. Intense irradiation of a counter with 6 Mev x-rays caused only a slight increase in the maximum noise level already present from the photomultiplier tube. The behaviour of the counter as a fast neutron detector has been investigated using an uncollimated beam of 4.1 Mev neutrons. Pulses from recoiling protons and C¹² nuclei were observed as well as the He⁴ recoils.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Construction details of a 5" diameter 1.7 litre gas scintillation counter are given. The behaviour of the counter when containing He⁴ gas and a mixture of He⁴ and 10% Xe at various total pressures has been investigated. Two 5" photomultiplier tubes and a variety of different gas purifiers were tested in an attempt to obtain the best possible resolution. The pulse height was found to depend sensitively on the purification procedure adopted. A resolution of 10% for the Po²¹⁰ α-peak has been attained in two different chambers containing He⁴ plus 10% Xe. The voltage pulses rose in ≤300 nsec. Intense irradiation of a counter with 6 Mev x-rays caused only a slight increase in the maximum noise level already present from the photomultiplier tube. The behaviour of the counter as a fast neutron detector has been investigated using an uncollimated beam of 4.1 Mev neutrons. Pulses from recoiling protons and C¹² nuclei were observed as well as the He⁴ recoils.

Key concepts: Scintillation, Scintillation counter, Environmental science, Physics, Optics, Detector

Related papers

Back to paper searchBrowse research topicsOriginal source
Gas scintillation counters — Research Paper | ScholarLens