2015Heat Transfer ResearchRequires access

JET ARRAY IMPINGEMENT COOLING LOCAL NUSSELT NUMBER VARIATIONS: EFFECTS OF HOLE ARRAY SPACING, JET-TO-TARGET PLATE DISTANCE, AND REYNOLDS NUMBER

Mary Jennerjohn, Jun-Sik Lee, Zhong Ren, Phillip M. Ligrani, Mark McQuilling, Michael Fox, Hee-Koo Moon

Open publisher page 8 citations

Abstract

Discussed in the article are the combined and separate effects of hole array spacing, jet-to-target plate distance, and Reynolds number on the local surface heat transfer rate for an impinging jet array. The array of impinging jets is directed to one flat surface of a channel which is bounded on three sides. Considered are the Reynolds numbers ranging from 8000 to 50,000, jet-to-target plate distances of 1.5D, 3.0D, 5.0D, and 8.0D, and the streamwise and spanwise hole spacing of 5D, 8D, and 12D, where D is the impingement hole diameter. Also included is a conduction analysis of the impingement cooling array target surface. In general, the local Nusselt numbers generally increase at each x/D location as either the Reynolds number increases, or as the X/D = Y/D hole spacing decreases. The highest Nusselt numbers are generally present at Z/D = 3.0 for Rej values of 8200, 20,000, and 30,000. When Rej = 52,000, the highest measured Nusselt number values are generally present for Z/D of either 1.5, 3.0, or 5.0, depending on the magnitudes of Rej, X/D, Y/D, and streamwise location x/D. The cumulative accumulations of crossflows, from sequential rows of jets, result in sequentially decreasing periodic Nusselt number variations with streamwise development. When examined at a particular value of Rej, the streamwise locations of the local maximum Nusselt numbers also shift to larger x/D locations as Z/D, the normalized jet-to-target distance, increases. The overall result is a complex dependence of local Nusselt numbers on the hole array spacing, jet-to-target plate distance, and impingement jet Reynolds number.

About this research paper

What this paper is about

Discussed in the article are the combined and separate effects of hole array spacing, jet-to-target plate distance, and Reynolds number on the local surface heat transfer rate for an impinging jet array. The array of impinging jets is directed to one flat surface of a channel which is bounded on three sides. Considered are the Reynolds numbers ranging from 8000 to 50,000, jet-to-target plate distances of 1.5D, 3.0D, 5.0D, and 8.0D, and the streamwise and spanwise hole spacing of 5D, 8D, and 12D, where D is the impingement hole diameter. Also included is a conduction analysis of the impingement cooling array target surface. In general, the local Nusselt numbers generally increase at each x/D location as either the Reynolds number increases, or as the X/D = Y/D hole spacing decreases. The highest Nusselt numbers are generally present at Z/D = 3.0 for Rej values of 8200, 20,000, and 30,000. When Rej = 52,000, the highest measured Nusselt number values are generally present for Z/D of either 1.5, 3.0, or 5.0, depending on the magnitudes of Rej, X/D, Y/D, and streamwise location x/D. The cumulative accumulations of crossflows, from sequential rows of jets, result in sequentially decreasing periodic Nusselt number variations with streamwise development. When examined at a particular value of Rej, the streamwise locations of the local maximum Nusselt numbers also shift to larger x/D locations as Z/D, the normalized jet-to-target distance, increases. The overall result is a complex dependence of local Nusselt numbers on the hole array spacing, jet-to-target plate distance, and impingement jet Reynolds number.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Discussed in the article are the combined and separate effects of hole array spacing, jet-to-target plate distance, and Reynolds number on the local surface heat transfer rate for an impinging jet array. The array of impinging jets is directed to one flat surface of a channel which is bounded on three sides. Considered are the Reynolds numbers ranging from 8000 to 50,000, jet-to-target plate distances of 1.5D, 3.0D, 5.0D, and 8.0D, and the streamwise and spanwise hole spacing of 5D, 8D, and 12D, where D is the impingement hole diameter. Also included is a conduction analysis of the impingement cooling array target surface. In general, the local Nusselt numbers generally increase at each x/D location as either the Reynolds number increases, or as the X/D = Y/D hole spacing decreases. The highest Nusselt numbers are generally present at Z/D = 3.0 for Rej values of 8200, 20,000, and 30,000. When Rej = 52,000, the highest measured Nusselt number values are generally present for Z/D of either 1.5, 3.0, or 5.0, depending on the magnitudes of Rej, X/D, Y/D, and streamwise location x/D. The cumulative accumulations of crossflows, from sequential rows of jets, result in sequentially decreasing periodic Nusselt number variations with streamwise development. When examined at a particular value of Rej, the streamwise locations of the local maximum Nusselt numbers also shift to larger x/D locations as Z/D, the normalized jet-to-target distance, increases. The overall result is a complex dependence of local Nusselt numbers on the hole array spacing, jet-to-target plate distance, and impingement jet Reynolds number.

Key concepts: Nusselt number, Reynolds number, Jet (fluid), Mechanics, Physics, Heat transfer, Turbulence