2002•Veterinární MedicínaOpen access

Comparison of the detection and quantification of rabies antibodies in canine sera

Anna Ondrejková, Judit Süli, R. Ondrejka, Z. Beníšek, Richard Franka, Štefan Švrček, Marián Maďar, Andrej Bugarský

Open full text 14 citations

Abstract

Rabies antibodies in canine sera were detected and quantified by methods: virus neutralisation test on mice (VNT), rapid fluorescence focus inhibition test (RFFIT), and fluorescent antibody virus neutralisation (FAVN). The results of rabies antibodies levels in non-vaccinated dogs obtained by all three methods were in correlation. The comparison of rabies antibody titres determined in vaccinated dogs using VNT and FAVN methods showed 86.6% correspondence, while those obtained by RFFIT and FAVN methods corresponded in almost 95% of cases.

About this research paper

What this paper is about

Rabies antibodies in canine sera were detected and quantified by methods: virus neutralisation test on mice (VNT), rapid fluorescence focus inhibition test (RFFIT), and fluorescent antibody virus neutralisation (FAVN). The results of rabies antibodies levels in non-vaccinated dogs obtained by all three methods were in correlation. The comparison of rabies antibody titres determined in vaccinated dogs using VNT and FAVN methods showed 86.6% correspondence, while those obtained by RFFIT and FAVN methods corresponded in almost 95% of cases.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Rabies antibodies in canine sera were detected and quantified by methods: virus neutralisation test on mice (VNT), rapid fluorescence focus inhibition test (RFFIT), and fluorescent antibody virus neutralisation (FAVN). The results of rabies antibodies levels in non-vaccinated dogs obtained by all three methods were in correlation. The comparison of rabies antibody titres determined in vaccinated dogs using VNT and FAVN methods showed 86.6% correspondence, while those obtained by RFFIT and FAVN methods corresponded in almost 95% of cases.

Key concepts: Rabies virus, Rabies, Virology, Antibody, Neutralization, Lyssavirus, Medicine, Virus

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of the detection and quantification of rabies antibodies in canine sera — Research Paper | ScholarLens