2015•Research Journal of Pharmacy and TechnologyOpen access

Simultaneous Estimation of Naproxen and Esomeprazole by RP-HPLC and its Validation

D Sri Lakshmi, Jane T Jacob, D Srinivas, D. Satyanarayana

Open full text 1 citations

Abstract

A simple, accurate, economical and precise reverse phase high performance liquid chromatographic (RP-HPLC) method has been developed for the simultaneous determination of Naproxen and Esomeprazole. The separation was achieved on Agilent CN column (250 x 4.6 mm, 5 μm) as stationary phase with a mobile phase comprising of Acetonitrile: K2HPO4: KH2PO4 (60: 20: 20) in an isocratic mode, at a flow rate of 2 ml/min. The detection was monitored at 257 nm. The retention time of Naproxen and Esomeprazole were 2.22 min and 3.24 min respectively. The linearity was found to be in the range of 150–350 μg/ml and 6–14 μg/ml for Naproxen and Esomeprazole respectively with correlation coefficient of 0.999. The proposed method was validated according to ICH guidelines for parameters like linearity, accuracy, precision and specificity. All validation parameters were within the acceptable range. The developed method was successfully applied for the estimation of Naproxen and Esomeprazole in pure and pharmaceutical dosage form.

About this research paper

What this paper is about

A simple, accurate, economical and precise reverse phase high performance liquid chromatographic (RP-HPLC) method has been developed for the simultaneous determination of Naproxen and Esomeprazole. The separation was achieved on Agilent CN column (250 x 4.6 mm, 5 μm) as stationary phase with a mobile phase comprising of Acetonitrile: K2HPO4: KH2PO4 (60: 20: 20) in an isocratic mode, at a flow rate of 2 ml/min. The detection was monitored at 257 nm. The retention time of Naproxen and Esomeprazole were 2.22 min and 3.24 min respectively. The linearity was found to be in the range of 150–350 μg/ml and 6–14 μg/ml for Naproxen and Esomeprazole respectively with correlation coefficient of 0.999. The proposed method was validated according to ICH guidelines for parameters like linearity, accuracy, precision and specificity. All validation parameters were within the acceptable range. The developed method was successfully applied for the estimation of Naproxen and Esomeprazole in pure and pharmaceutical dosage form.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, accurate, economical and precise reverse phase high performance liquid chromatographic (RP-HPLC) method has been developed for the simultaneous determination of Naproxen and Esomeprazole. The separation was achieved on Agilent CN column (250 x 4.6 mm, 5 μm) as stationary phase with a mobile phase comprising of Acetonitrile: K2HPO4: KH2PO4 (60: 20: 20) in an isocratic mode, at a flow rate of 2 ml/min. The detection was monitored at 257 nm. The retention time of Naproxen and Esomeprazole were 2.22 min and 3.24 min respectively. The linearity was found to be in the range of 150–350 μg/ml and 6–14 μg/ml for Naproxen and Esomeprazole respectively with correlation coefficient of 0.999. The proposed method was validated according to ICH guidelines for parameters like linearity, accuracy, precision and specificity. All validation parameters were within the acceptable range. The developed method was successfully applied for the estimation of Naproxen and Esomeprazole in pure and pharmaceutical dosage form.

Key concepts: Esomeprazole, Naproxen, Estimation, Mathematics, Medicine, Chromatography, Statistics, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Estimation of Naproxen and Esomeprazole by RP-HPLC and its Validation — Research Paper | ScholarLens