A Study on the Flash Point and Spontaneous Ignition Determination of Diethylene Glycol
Jung-Hun Kim, Jae-Wook Choi
Abstract
Jung-Hun Kim, Jae-Wook Choi
Abstract
This study investigates the main factors of fire prevention, such as spontaneous ignition and flash point, while using Diehylene Glycol (DEG) as the antifreeze for automobile and industrial machines. Our results show the flash point of 142℃ and the minimum ignition temperature of 388℃ in the range of 130㎕ ~ 150㎕. By increasing temperature to ignite in 1 second, an instantaneous ignition temperature of the sample is 569℃ in the sample amount of 140㎕.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This study investigates the main factors of fire prevention, such as spontaneous ignition and flash point, while using Diehylene Glycol (DEG) as the antifreeze for automobile and industrial machines. Our results show the flash point of 142℃ and the minimum ignition temperature of 388℃ in the range of 130㎕ ~ 150㎕. By increasing temperature to ignite in 1 second, an instantaneous ignition temperature of the sample is 569℃ in the sample amount of 140㎕.
Key concepts: Diethylene glycol, Flash point, Flash (photography), Spontaneous combustion, Ignition system, Engineering, Ethylene glycol, Thermodynamics