Thermodynamic temperature by primary radiometry
K. Anhalt, G. Machin
Abstract
K. Anhalt, G. Machin
Abstract
Above the freezing temperature of silver (1234.93 K), the International Temperature Scale of 1990 (ITS-90) gives a temperature, T90, in terms of a defining fixed-point blackbody and Planck's law of thermal radiation in ratio form. Alternatively, by using Planck's law directly, thermodynamic temperature can be determined by applying radiation detectors calibrated in absolute terms for their spectral responsivity. With the advent of high-quality semiconductor photodiodes and the development of high-accuracy cryogenic radiometers during the last two decades radiometric detector standards with very small uncertainties in the range of 0.01-0.02% have been developed for direct, absolute radiation thermometry with uncertainties comparable to those for the realization of the ITS-90. This article gives an overview of a number of design variants of different types of radiometer used for primary radiometry and describes their calibration. Furthermore, details and requirements regarding the experimental procedure for obtaining low uncertainty thermodynamic temperatures with these radiometers are presented, noting that such radiometers can also be used at temperatures well below the silver point. Finally, typical results obtained by these methods are reviewed.
OpenAlex reports 28 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Above the freezing temperature of silver (1234.93 K), the International Temperature Scale of 1990 (ITS-90) gives a temperature, T90, in terms of a defining fixed-point blackbody and Planck's law of thermal radiation in ratio form. Alternatively, by using Planck's law directly, thermodynamic temperature can be determined by applying radiation detectors calibrated in absolute terms for their spectral responsivity. With the advent of high-quality semiconductor photodiodes and the development of high-accuracy cryogenic radiometers during the last two decades radiometric detector standards with very small uncertainties in the range of 0.01-0.02% have been developed for direct, absolute radiation thermometry with uncertainties comparable to those for the realization of the ITS-90. This article gives an overview of a number of design variants of different types of radiometer used for primary radiometry and describes their calibration. Furthermore, details and requirements regarding the experimental procedure for obtaining low uncertainty thermodynamic temperatures with these radiometers are presented, noting that such radiometers can also be used at temperatures well below the silver point. Finally, typical results obtained by these methods are reviewed.
Key concepts: Radiometer, Radiometry, Thermodynamic temperature, International Temperature Scale of 1990, Black-body radiation, Calibration, Planck, Detector