Unimolecular Chemically Modified DNA Fluorescent Probe for One-Step Quantitative Measurement of the Activity of Human Apurinic/Apyrimidinic Endonuclease 1 in Biological Samples
Simin Fang, Lu Chen, Meiping Zhao
Abstract
Open-access reader
Simin Fang, Lu Chen, Meiping Zhao
Abstract
Open-access reader
A novel DNA structure containing a 3' internal-loop modified abasic site has been constructed which enables effective differentiation between apurinic/apyrimidinic endonuclease (APE1) and nonspecific endonuclease (DNase I). When this unique substrate structure is employed, a double-loop frayed-end chimeric fluorescent probe is successfully developed for quantitative measurement of the activity of APE1 in biological samples without the need of additional cleanup or preconcentration steps. The method is simple and rapid and has a single-step with a linear working range between 0.1 and 5.0 U/mL and a lower limit of detection of 0.1 U/mL. It holds great potential in real-time monitoring of the variation of intracellular and extracellular APE1, which will be very useful for further understanding of the DNA repair pathways in different organisms.
OpenAlex reports 54 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A novel DNA structure containing a 3' internal-loop modified abasic site has been constructed which enables effective differentiation between apurinic/apyrimidinic endonuclease (APE1) and nonspecific endonuclease (DNase I). When this unique substrate structure is employed, a double-loop frayed-end chimeric fluorescent probe is successfully developed for quantitative measurement of the activity of APE1 in biological samples without the need of additional cleanup or preconcentration steps. The method is simple and rapid and has a single-step with a linear working range between 0.1 and 5.0 U/mL and a lower limit of detection of 0.1 U/mL. It holds great potential in real-time monitoring of the variation of intracellular and extracellular APE1, which will be very useful for further understanding of the DNA repair pathways in different organisms.
Key concepts: AP site, Endonuclease, Chemistry, DNA, Detection limit, Fluorescence, Biophysics, DNA damage