2015Asian Journal of Pharmacy and TechnologyOpen access

A validated stability indicating RP-HPLC method for simultaneous estimation of Clinidipine and Valsartan in bulk and combined tablet dosage forms

G. Kumara Swamy, J. M. Rajendra Kumar, J. V. L. N. Seshagiri Rao

Open full text 8 citations

Abstract

The simple, accurate and precise, isocratic RP-HPLC method has been developed and validated for simultaneous estimation of Clinidipine and Valsartan in bulk and tablets dosage forms. The chromatographic separation was achieved on an Waters symmetry C18 (150x4.6 Id, 3.5μ) with a composition of Acetonitrile: phosphate buffer pH 3.5 adjusted with orthophosphoric acid (70:30, v/v) as mobile phase; at a flow rate of 1.0 ml/min. PDA detection of separtion was performed at 254 nm. The retention times were 2.33 and 3.55 minutes. for Clinidipine and Valsartan respectively. Calibration curves were linear (r2>0.998) over the concentration range 1.2–6.0 μg/ml for Clinidipine and 10–50μg/ml Valsartan. The method was validated for accuracy, precision, specificity, linearity, and sensitivity. The proposed method was successfully used for quantitative analysis of tablets. No interference from any component of pharmaceutical dosage form was observed. Validation studies revealed that method is specific, rapid, reliable, and reproducible. The high recovery and low relative standard deviation confirm the suitability of the method for routine determination of Clinidipine and Valsartan in bulk drug and tablet dosage form.

About this research paper

What this paper is about

The simple, accurate and precise, isocratic RP-HPLC method has been developed and validated for simultaneous estimation of Clinidipine and Valsartan in bulk and tablets dosage forms. The chromatographic separation was achieved on an Waters symmetry C18 (150x4.6 Id, 3.5μ) with a composition of Acetonitrile: phosphate buffer pH 3.5 adjusted with orthophosphoric acid (70:30, v/v) as mobile phase; at a flow rate of 1.0 ml/min. PDA detection of separtion was performed at 254 nm. The retention times were 2.33 and 3.55 minutes. for Clinidipine and Valsartan respectively. Calibration curves were linear (r2>0.998) over the concentration range 1.2–6.0 μg/ml for Clinidipine and 10–50μg/ml Valsartan. The method was validated for accuracy, precision, specificity, linearity, and sensitivity. The proposed method was successfully used for quantitative analysis of tablets. No interference from any component of pharmaceutical dosage form was observed. Validation studies revealed that method is specific, rapid, reliable, and reproducible. The high recovery and low relative standard deviation confirm the suitability of the method for routine determination of Clinidipine and Valsartan in bulk drug and tablet dosage form.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The simple, accurate and precise, isocratic RP-HPLC method has been developed and validated for simultaneous estimation of Clinidipine and Valsartan in bulk and tablets dosage forms. The chromatographic separation was achieved on an Waters symmetry C18 (150x4.6 Id, 3.5μ) with a composition of Acetonitrile: phosphate buffer pH 3.5 adjusted with orthophosphoric acid (70:30, v/v) as mobile phase; at a flow rate of 1.0 ml/min. PDA detection of separtion was performed at 254 nm. The retention times were 2.33 and 3.55 minutes. for Clinidipine and Valsartan respectively. Calibration curves were linear (r2>0.998) over the concentration range 1.2–6.0 μg/ml for Clinidipine and 10–50μg/ml Valsartan. The method was validated for accuracy, precision, specificity, linearity, and sensitivity. The proposed method was successfully used for quantitative analysis of tablets. No interference from any component of pharmaceutical dosage form was observed. Validation studies revealed that method is specific, rapid, reliable, and reproducible. The high recovery and low relative standard deviation confirm the suitability of the method for routine determination of Clinidipine and Valsartan in bulk drug and tablet dosage form.

Key concepts: Dosage form, Valsartan, Chromatography, Mathematics, High-performance liquid chromatography, Chemistry, Statistics, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
A validated stability indicating RP-HPLC method for simultaneous estimation of Clinidipine and Valsartan in bulk and combined tablet dosage forms — Research Paper | ScholarLens