Reproducibility of three different methods of measuring baroreflex sensitivity in normal subjects
Sue Lord, Richard H. Clayton, M Hall, Joanne Gray, Alan Murray, Janet M. McComb, Rose Anne Kenny
Abstract
Sue Lord, Richard H. Clayton, M Hall, Joanne Gray, Alan Murray, Janet M. McComb, Rose Anne Kenny
Abstract
1. Baroreflex sensitivity is a useful tool for investigating cardiovascular reflexes in a number of clinical settings. Several different methods of measuring baroreflex sensitivity are available. In order to determine a clinically useful non-invasive method of measuring baroreflex sensitivity we compared two methods (spectral analysis and the Valsalva manoeuvre) with regard to reproducibility, agreement with a standard invasive method (phenylephrine infusion) and failure rate.2.Twenty-six healthy subjects aged 22 to 63 years attended on three separate occasions for measurement of baroreflex sensitivity using the different methods. The effect of a recent head-up tilt on baroreflex sensitivity was measured.3. Reproducibility was best for the low-frequency component of the spectral method [coefficient of variation 25.0% (range 3.5-42.4%)] and worst for the Valsalva method [coefficient of variation 29.3% (range 13.8-93.1%)]. Both non-invasive methods overestimated values compared with the phenylephrine method [bias of low-frequency component of the spectral method, 1.17 (0.38-3.6); bias of the Valsalva method, 1.13 (0.19-6.7)]. The high-frequency component of the spectral method did not agree with the phenylephrine method.4. The spectral analysis method had the fewest failures (seven subjects with a failure on at least one occasion), and the phenylephrine method the most (16 subjects with a failure on at least one occasion). A short head-up tilt did not affect the subsequent non-invasive measurement of baroreflex sensitivity.5. It was concluded that the low-frequency component of the spectral method was the most clinically useful non-invasive measurement of baroreflex sensitivity.
OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
1. Baroreflex sensitivity is a useful tool for investigating cardiovascular reflexes in a number of clinical settings. Several different methods of measuring baroreflex sensitivity are available. In order to determine a clinically useful non-invasive method of measuring baroreflex sensitivity we compared two methods (spectral analysis and the Valsalva manoeuvre) with regard to reproducibility, agreement with a standard invasive method (phenylephrine infusion) and failure rate.2.Twenty-six healthy subjects aged 22 to 63 years attended on three separate occasions for measurement of baroreflex sensitivity using the different methods. The effect of a recent head-up tilt on baroreflex sensitivity was measured.3. Reproducibility was best for the low-frequency component of the spectral method [coefficient of variation 25.0% (range 3.5-42.4%)] and worst for the Valsalva method [coefficient of variation 29.3% (range 13.8-93.1%)]. Both non-invasive methods overestimated values compared with the phenylephrine method [bias of low-frequency component of the spectral method, 1.17 (0.38-3.6); bias of the Valsalva method, 1.13 (0.19-6.7)]. The high-frequency component of the spectral method did not agree with the phenylephrine method.4. The spectral analysis method had the fewest failures (seven subjects with a failure on at least one occasion), and the phenylephrine method the most (16 subjects with a failure on at least one occasion). A short head-up tilt did not affect the subsequent non-invasive measurement of baroreflex sensitivity.5. It was concluded that the low-frequency component of the spectral method was the most clinically useful non-invasive measurement of baroreflex sensitivity.
Key concepts: Baroreflex, Phenylephrine, Reproducibility, Medicine, Coefficient of variation, Valsalva maneuver, Sensitivity (control systems), Anesthesia