Development and Validation of RP-HPLC Method for the Simultaneous Estimation of Irbesartan and Atorvastatin in Synthetic Mixture
Virani Paras, Rajanit Sojitra, Bhadresh Savaj, Raj Hashumati, Jain Vineet, Patel Kalpesh, Vishnu Sutariya
Abstract
Virani Paras, Rajanit Sojitra, Bhadresh Savaj, Raj Hashumati, Jain Vineet, Patel Kalpesh, Vishnu Sutariya
Abstract
A simple, accurate, rapid and precise reverse phase high performance liquid chromatographic method was developed for simultaneous estimation of Irbesartan and Atorvastatin in synthetic mixture. Inertsil C18, 150 mm x 4.6 mm, 5 μm particle size in gradient mode with mobile phase Acetonitrile: 0.1% Formic acid (40: 60 v/v) and pH adjusted to 3.5 ± 0.1 with orthophosphoric acid was used. The flow rate was 1.0 ml/min and absorbance of individual component was measured at 262 nm. The retention times of Irbesartan and Atorvastatin were found to be 3.993 and 7.733 min, respectively. Linearity for Irbesartan and Atorvastatin was in the range of 400 -800 and 50–100μg/ml with correlation coefficient values 0.9995and 0.9994, the percentage recovery obtained was 99.88and 99.70%, respectively.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simple, accurate, rapid and precise reverse phase high performance liquid chromatographic method was developed for simultaneous estimation of Irbesartan and Atorvastatin in synthetic mixture. Inertsil C18, 150 mm x 4.6 mm, 5 μm particle size in gradient mode with mobile phase Acetonitrile: 0.1% Formic acid (40: 60 v/v) and pH adjusted to 3.5 ± 0.1 with orthophosphoric acid was used. The flow rate was 1.0 ml/min and absorbance of individual component was measured at 262 nm. The retention times of Irbesartan and Atorvastatin were found to be 3.993 and 7.733 min, respectively. Linearity for Irbesartan and Atorvastatin was in the range of 400 -800 and 50–100μg/ml with correlation coefficient values 0.9995and 0.9994, the percentage recovery obtained was 99.88and 99.70%, respectively.
Key concepts: Irbesartan, Atorvastatin, Chromatography, Formic acid, Chemistry, Correlation coefficient, Retention time, Dosage form