EVALUATION OF FEMORAL PERIPROSTHETIC STRESS-SHIELDING FOLLOWING UNILATERAL CEMENTLESS TOTAL HIP REPLACEMENT USING DEXA SCAN

Vinay Kumar, Rajesh Malhotra, Swati Bhan

Open publisher page 0 citations

Abstract

Background: Joint replacements are being performed on ever younger patients at a time when average expectancy of life is continuing to rise. Any reduction in the strength and mass of periprosthetic bone could threaten the longevity of implant by predisposing to loosening and migration of prosthesis, periprosthetic fracture and problems in revision arthroplasty. Aims & Objectives: This study aims to analyse the femoral periprosthetic stress-shielding following unilateral cementless total hip replacement using DEXA scan by quantifying the changes in bone mineral density around femoral component over a period of one year and identify the factors influencing the bone loss. Material & Method: Femoral periprosthetic bone mineral density was measured in the seven Gruen Zones with DEXA scan at 2 weeks, 3 months and 1 year after surgery in 20 patients who had undergone unilateral cementless total hip replacement, of which 10 patients had been implanted with 4/5 th porous coated CoCr stems and other 10 patients with 1/3 rd porous coated titanium alloy stems. Results: At both 3 months and one year postoperatively, bone loss due to stress-shielding was seen in both stems with maximum loss in zone VII and minimum in zone III, IV, V. The maximum mean percentage bone mineral density loss in 4/5 th porous coated CoCr stems in zone VII was 16.03% at 3 month and 22.42% at 1 year as compared to loss of 10.07% and 16.01% in 1/3 rd porous coated Ti alloy stems. Increased bone loss was seen in patients who had larger diameter stem (> 13.0 mm) and in patients with low bone mineral density in the unoperated hip. Conclusion: Bone loss as a result of stress-shielding is more pronounced in 4/5 th porous coated CoCr stems as compared to 1/3 rd porous coated titanium alloy stems.

About this research paper

What this paper is about

Background: Joint replacements are being performed on ever younger patients at a time when average expectancy of life is continuing to rise. Any reduction in the strength and mass of periprosthetic bone could threaten the longevity of implant by predisposing to loosening and migration of prosthesis, periprosthetic fracture and problems in revision arthroplasty. Aims & Objectives: This study aims to analyse the femoral periprosthetic stress-shielding following unilateral cementless total hip replacement using DEXA scan by quantifying the changes in bone mineral density around femoral component over a period of one year and identify the factors influencing the bone loss. Material & Method: Femoral periprosthetic bone mineral density was measured in the seven Gruen Zones with DEXA scan at 2 weeks, 3 months and 1 year after surgery in 20 patients who had undergone unilateral cementless total hip replacement, of which 10 patients had been implanted with 4/5 th porous coated CoCr stems and other 10 patients with 1/3 rd porous coated titanium alloy stems. Results: At both 3 months and one year postoperatively, bone loss due to stress-shielding was seen in both stems with maximum loss in zone VII and minimum in zone III, IV, V. The maximum mean percentage bone mineral density loss in 4/5 th porous coated CoCr stems in zone VII was 16.03% at 3 month and 22.42% at 1 year as compared to loss of 10.07% and 16.01% in 1/3 rd porous coated Ti alloy stems. Increased bone loss was seen in patients who had larger diameter stem (> 13.0 mm) and in patients with low bone mineral density in the unoperated hip. Conclusion: Bone loss as a result of stress-shielding is more pronounced in 4/5 th porous coated CoCr stems as compared to 1/3 rd porous coated titanium alloy stems.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: Joint replacements are being performed on ever younger patients at a time when average expectancy of life is continuing to rise. Any reduction in the strength and mass of periprosthetic bone could threaten the longevity of implant by predisposing to loosening and migration of prosthesis, periprosthetic fracture and problems in revision arthroplasty. Aims & Objectives: This study aims to analyse the femoral periprosthetic stress-shielding following unilateral cementless total hip replacement using DEXA scan by quantifying the changes in bone mineral density around femoral component over a period of one year and identify the factors influencing the bone loss. Material & Method: Femoral periprosthetic bone mineral density was measured in the seven Gruen Zones with DEXA scan at 2 weeks, 3 months and 1 year after surgery in 20 patients who had undergone unilateral cementless total hip replacement, of which 10 patients had been implanted with 4/5 th porous coated CoCr stems and other 10 patients with 1/3 rd porous coated titanium alloy stems. Results: At both 3 months and one year postoperatively, bone loss due to stress-shielding was seen in both stems with maximum loss in zone VII and minimum in zone III, IV, V. The maximum mean percentage bone mineral density loss in 4/5 th porous coated CoCr stems in zone VII was 16.03% at 3 month and 22.42% at 1 year as compared to loss of 10.07% and 16.01% in 1/3 rd porous coated Ti alloy stems. Increased bone loss was seen in patients who had larger diameter stem (> 13.0 mm) and in patients with low bone mineral density in the unoperated hip. Conclusion: Bone loss as a result of stress-shielding is more pronounced in 4/5 th porous coated CoCr stems as compared to 1/3 rd porous coated titanium alloy stems.

Key concepts: Periprosthetic, Stress shielding, Medicine, Bone mineral, Implant, Surgery, Prosthesis, Total hip replacement