2016Indoor and Built EnvironmentRequires access

Simulation of indoor comfort level in a building cooled by a cooling tower–concrete core cooling system under hot–semiarid climatic conditions

D.G. Leo Samuel, S. M. Shiva Nagendra, M.P. Maiya

Open publisher page 17 citations

Abstract

Concrete core cooling system is an energy efficient alternative to the conventional mechanical cooling system. It provides better comfort due to direct absorption of radiation load, low indoor air velocity, apt vertical temperature gradient and absence of noise. It can be operated at relatively higher water temperature, which facilitates the use of passive cooling strategies. In this study, a cooling tower, which is an ‘evaporative cooling system’, is preferred over other passive cooling options due to its better cooling performance in dry regions and its ability to operate all through the day. This paper presents the results of computational fluid dynamic analysis of a room cooled by concrete core cooling system supported by a cooling tower. The study reveals that for a typical hot–semiarid summer climatic condition in India, the system reduces the average indoor air temperature to a comfortable range of 23.5 to 28℃ from an uncomfortable range of 35.3 to 41℃ in a building without cooling. The average predicted percentage of dissatisfied falls from 99.7% in a building without cooling, to 37.3% if roof and floor of a building are cooled with concrete core cooling system and further to 6.3% if all surfaces are cooled with concrete core cooling system.

About this research paper

What this paper is about

Concrete core cooling system is an energy efficient alternative to the conventional mechanical cooling system. It provides better comfort due to direct absorption of radiation load, low indoor air velocity, apt vertical temperature gradient and absence of noise. It can be operated at relatively higher water temperature, which facilitates the use of passive cooling strategies. In this study, a cooling tower, which is an ‘evaporative cooling system’, is preferred over other passive cooling options due to its better cooling performance in dry regions and its ability to operate all through the day. This paper presents the results of computational fluid dynamic analysis of a room cooled by concrete core cooling system supported by a cooling tower. The study reveals that for a typical hot–semiarid summer climatic condition in India, the system reduces the average indoor air temperature to a comfortable range of 23.5 to 28℃ from an uncomfortable range of 35.3 to 41℃ in a building without cooling. The average predicted percentage of dissatisfied falls from 99.7% in a building without cooling, to 37.3% if roof and floor of a building are cooled with concrete core cooling system and further to 6.3% if all surfaces are cooled with concrete core cooling system.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Concrete core cooling system is an energy efficient alternative to the conventional mechanical cooling system. It provides better comfort due to direct absorption of radiation load, low indoor air velocity, apt vertical temperature gradient and absence of noise. It can be operated at relatively higher water temperature, which facilitates the use of passive cooling strategies. In this study, a cooling tower, which is an ‘evaporative cooling system’, is preferred over other passive cooling options due to its better cooling performance in dry regions and its ability to operate all through the day. This paper presents the results of computational fluid dynamic analysis of a room cooled by concrete core cooling system supported by a cooling tower. The study reveals that for a typical hot–semiarid summer climatic condition in India, the system reduces the average indoor air temperature to a comfortable range of 23.5 to 28℃ from an uncomfortable range of 35.3 to 41℃ in a building without cooling. The average predicted percentage of dissatisfied falls from 99.7% in a building without cooling, to 37.3% if roof and floor of a building are cooled with concrete core cooling system and further to 6.3% if all surfaces are cooled with concrete core cooling system.

Key concepts: Cooling tower, Passive cooling, Evaporative cooler, Environmental science, Water cooling, Roof, Free cooling, Core (optical fiber)

Related papers

Back to paper searchBrowse research topicsOriginal source
Simulation of indoor comfort level in a building cooled by a cooling tower–concrete core cooling system under hot–semiarid climatic conditions — Research Paper | ScholarLens