[Analysis on reliability and validity of SF-36 scale in urban residents].
Shan Wang, Wenjie Fan, Wanqi Yu, Jian Li, Dong-Hui Xu, Hongyan Cao, Ying Xi, Xiuyang Li
Abstract
Shan Wang, Wenjie Fan, Wanqi Yu, Jian Li, Dong-Hui Xu, Hongyan Cao, Ying Xi, Xiuyang Li
Abstract
OBJECTIVE: To evaluate the reliability and validity of SF-36 scale in urban residents, and provide reference for the selection of suitable health measure tools for urban residents. METHODS: Multi-stage cluster stratified sampling was conducted to select the residents aged ≥18 years in three urbanized communities of Hangzhou. SF-36 scale was used for the measurement of the quality of life and Spearman-Brown and Cronbach' s α coefficients were used for the evaluation of split-half reliability and internal consistency reliability. The convergent and discriminative validity were evaluated by using the success rate of experiments and the criterion-related validity was evaluated with correlation analysis and non-parameter test. Structural equation modeling was used in the evaluation of contract validity. RESULTS: SF-36 scale had good split-half reliability (R=0.94) and internal-consistency reliability (except for bodily pain and vitality, Cronbach's α range: 0.70-0.91). The convergent validity (88.57%), discriminate validity (successful rates 90.61%) and the criterion-related validity (γs=0.56, the score was consistent with the self-reported health status) were good. Second-order confirmatory factor analysis model was not well-fitted (GFI= 0.721, AGFI= 0.682, CFI= 0.731, RMR= 0.084, RMSEA= 0.098), indicating that the construct validity was poor. CONCLUSION: The reliability, consolidation validity, discrimination validity and criterion-related validity of SF-36 scale were good, while the construct validity was poor. Improvement is needed when the scale is used for urban residents.
OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To evaluate the reliability and validity of SF-36 scale in urban residents, and provide reference for the selection of suitable health measure tools for urban residents. METHODS: Multi-stage cluster stratified sampling was conducted to select the residents aged ≥18 years in three urbanized communities of Hangzhou. SF-36 scale was used for the measurement of the quality of life and Spearman-Brown and Cronbach' s α coefficients were used for the evaluation of split-half reliability and internal consistency reliability. The convergent and discriminative validity were evaluated by using the success rate of experiments and the criterion-related validity was evaluated with correlation analysis and non-parameter test. Structural equation modeling was used in the evaluation of contract validity. RESULTS: SF-36 scale had good split-half reliability (R=0.94) and internal-consistency reliability (except for bodily pain and vitality, Cronbach's α range: 0.70-0.91). The convergent validity (88.57%), discriminate validity (successful rates 90.61%) and the criterion-related validity (γs=0.56, the score was consistent with the self-reported health status) were good. Second-order confirmatory factor analysis model was not well-fitted (GFI= 0.721, AGFI= 0.682, CFI= 0.731, RMR= 0.084, RMSEA= 0.098), indicating that the construct validity was poor. CONCLUSION: The reliability, consolidation validity, discrimination validity and criterion-related validity of SF-36 scale were good, while the construct validity was poor. Improvement is needed when the scale is used for urban residents.
Key concepts: Cronbach's alpha, Construct validity, Convergent validity, Criterion validity, Psychology, Confirmatory factor analysis, Statistics, Scale (ratio)