Thermal Management of a Motor Drive Power Module by Liquid Impingement Cooling
Avijit Bhunia, Chung-Lung Chen
Abstract
Avijit Bhunia, Chung-Lung Chen
Abstract
Thermal management of a 600V 25A power module by liquid jet impingement is investigated. Experiments are conducted on a module with resistive heat sources mimicking heat dissipation from IGBTs and diodes. An array of 36 DI water jets, 145 – 200µm diameter, impinging on the base plate of the module, demonstrates a 3X and 4X enhancement of the heat dissipation capability compared to the traditional cold plate and air-cooled heat sink respectively. If the power level is held constant, the device junction temperature is reduced by a factor of 3X. At a reduced system pressure (13% atmospheric), an efficient jet impingement boiling on the base plate leads to a device level (1cm 2 area) power density of 230W/cm 2 . The corresponding module volumetric power density is 6.7MW/m 3 , more than twice of water-cooled cold plate. Numerical simulations show that the liquid impingement cooling technique has potential to enhance the module output rating from its current level of 5.2KW to ~20KW and ~62KW, respectively for silicon and silicon carbide devices.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Thermal management of a 600V 25A power module by liquid jet impingement is investigated. Experiments are conducted on a module with resistive heat sources mimicking heat dissipation from IGBTs and diodes. An array of 36 DI water jets, 145 – 200µm diameter, impinging on the base plate of the module, demonstrates a 3X and 4X enhancement of the heat dissipation capability compared to the traditional cold plate and air-cooled heat sink respectively. If the power level is held constant, the device junction temperature is reduced by a factor of 3X. At a reduced system pressure (13% atmospheric), an efficient jet impingement boiling on the base plate leads to a device level (1cm 2 area) power density of 230W/cm 2 . The corresponding module volumetric power density is 6.7MW/m 3 , more than twice of water-cooled cold plate. Numerical simulations show that the liquid impingement cooling technique has potential to enhance the module output rating from its current level of 5.2KW to ~20KW and ~62KW, respectively for silicon and silicon carbide devices.
Key concepts: Computer cooling, Thermal management of electronic devices and systems, Power (physics), Automotive engineering, Thermal, Water cooling, Mechanical engineering, Environmental science