2014Eye & Contact Lens Science & Clinical PracticeRequires access

Assessment of Anterior Chamber Parameters After Cataract Surgery by Galilei Dual Scheimpflug Analyzer

Ramazan Yağc, Emre Güler, Feyza Uzun, Betül F. Gürağaç, Semra Acer, İbrahim F. Hepşen

Open publisher page 10 citations

Abstract

OBJECTIVE: To quantify the difference between anterior chamber parameters determined by the Galilei dual Scheimpflug analyzer after uneventful cataract surgery in normotensive eyes. METHODS: In this study, 39 eyes of 30 patients (11 men and 19 women) who had uneventful cataract surgery with phacoemulsification were evaluated preoperatively, and at 1 month postoperatively with the Galilei. We investigated the measurements including anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), and the 3-, 5-, and 7-mm corneal thickness (CT) preoperatively and postoperatively. RESULTS: The differences between ACD (P=0.01), ACA (P=0.07), ACV (P=0.01), and 7-mm CT (P=0.01), and intraocular pressure (P=0.03) were statistically significant after the first month of phacoemulsification. However, the differences between CCT (P=0.60), 3-mm CT (P=0.75), and 5-mm (P=0.17) CT were not statistically significant. CONCLUSIONS: After the first month of cataract surgery, a significant increase was observed in ACD, ACV, ACA, and 7-mm CT parameters, which were practically determined by a new noncontact Scheimpflug imagining system.

About this research paper

What this paper is about

OBJECTIVE: To quantify the difference between anterior chamber parameters determined by the Galilei dual Scheimpflug analyzer after uneventful cataract surgery in normotensive eyes. METHODS: In this study, 39 eyes of 30 patients (11 men and 19 women) who had uneventful cataract surgery with phacoemulsification were evaluated preoperatively, and at 1 month postoperatively with the Galilei. We investigated the measurements including anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), and the 3-, 5-, and 7-mm corneal thickness (CT) preoperatively and postoperatively. RESULTS: The differences between ACD (P=0.01), ACA (P=0.07), ACV (P=0.01), and 7-mm CT (P=0.01), and intraocular pressure (P=0.03) were statistically significant after the first month of phacoemulsification. However, the differences between CCT (P=0.60), 3-mm CT (P=0.75), and 5-mm (P=0.17) CT were not statistically significant. CONCLUSIONS: After the first month of cataract surgery, a significant increase was observed in ACD, ACV, ACA, and 7-mm CT parameters, which were practically determined by a new noncontact Scheimpflug imagining system.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To quantify the difference between anterior chamber parameters determined by the Galilei dual Scheimpflug analyzer after uneventful cataract surgery in normotensive eyes. METHODS: In this study, 39 eyes of 30 patients (11 men and 19 women) who had uneventful cataract surgery with phacoemulsification were evaluated preoperatively, and at 1 month postoperatively with the Galilei. We investigated the measurements including anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), and the 3-, 5-, and 7-mm corneal thickness (CT) preoperatively and postoperatively. RESULTS: The differences between ACD (P=0.01), ACA (P=0.07), ACV (P=0.01), and 7-mm CT (P=0.01), and intraocular pressure (P=0.03) were statistically significant after the first month of phacoemulsification. However, the differences between CCT (P=0.60), 3-mm CT (P=0.75), and 5-mm (P=0.17) CT were not statistically significant. CONCLUSIONS: After the first month of cataract surgery, a significant increase was observed in ACD, ACV, ACA, and 7-mm CT parameters, which were practically determined by a new noncontact Scheimpflug imagining system.

Key concepts: Scheimpflug principle, Phacoemulsification, Anterior chamber angle, Ophthalmology, Medicine, Cataract surgery, Intraocular pressure, Significant difference

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessment of Anterior Chamber Parameters After Cataract Surgery by Galilei Dual Scheimpflug Analyzer — Research Paper | ScholarLens