1995OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)Requires access

Analysis of gasoline for aromatic hydrocarbons by GC/MS and by low-EV-HR/MS

R. D. Grigsby, Ted B. McWilliams

Open publisher page 0 citations

Abstract

The United States Clean Air Act requires that finished gasoline be formulated to reduce ozone-reactive emissions and to lower gasoline toxicity. Mandated changes in gasoline composition include limiting the concentrations of benzene and total aromatics, as well as other restrictions on composition and volatility. A set of guidelines published by the U.S. Environmental Protection Agency has specified GC/MS for determining total aromatics content. Based on the EPA guidelines, the American Society for Losting and Materials has proposed a standard method for determining aromatics in gasoline by GC/MS. In this laboratory, the ASTM gasoline samples have been analyzed by GC/MS in a magnetic-sector instrument equipped with a capillary column. In addition, they have been analyzed by low eV-high resolution mass spectrometry with sample introduction through an all-glass expansion-volume inlet. Nominal 10 eV electron ionization was used in the low eV analysis and 70 eV electron ionization in the GC/MS analysis. The high-resolution data were obtained at a resolving power of 10,000. For both methods, internal standards were included with the samples and calibration curves were calculated using least squares with a spreadsheet program. As a further check, liquid chromatography was used to analyze the samples for benzene and toluene.

About this research paper

What this paper is about

The United States Clean Air Act requires that finished gasoline be formulated to reduce ozone-reactive emissions and to lower gasoline toxicity. Mandated changes in gasoline composition include limiting the concentrations of benzene and total aromatics, as well as other restrictions on composition and volatility. A set of guidelines published by the U.S. Environmental Protection Agency has specified GC/MS for determining total aromatics content. Based on the EPA guidelines, the American Society for Losting and Materials has proposed a standard method for determining aromatics in gasoline by GC/MS. In this laboratory, the ASTM gasoline samples have been analyzed by GC/MS in a magnetic-sector instrument equipped with a capillary column. In addition, they have been analyzed by low eV-high resolution mass spectrometry with sample introduction through an all-glass expansion-volume inlet. Nominal 10 eV electron ionization was used in the low eV analysis and 70 eV electron ionization in the GC/MS analysis. The high-resolution data were obtained at a resolving power of 10,000. For both methods, internal standards were included with the samples and calibration curves were calculated using least squares with a spreadsheet program. As a further check, liquid chromatography was used to analyze the samples for benzene and toluene.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The United States Clean Air Act requires that finished gasoline be formulated to reduce ozone-reactive emissions and to lower gasoline toxicity. Mandated changes in gasoline composition include limiting the concentrations of benzene and total aromatics, as well as other restrictions on composition and volatility. A set of guidelines published by the U.S. Environmental Protection Agency has specified GC/MS for determining total aromatics content. Based on the EPA guidelines, the American Society for Losting and Materials has proposed a standard method for determining aromatics in gasoline by GC/MS. In this laboratory, the ASTM gasoline samples have been analyzed by GC/MS in a magnetic-sector instrument equipped with a capillary column. In addition, they have been analyzed by low eV-high resolution mass spectrometry with sample introduction through an all-glass expansion-volume inlet. Nominal 10 eV electron ionization was used in the low eV analysis and 70 eV electron ionization in the GC/MS analysis. The high-resolution data were obtained at a resolving power of 10,000. For both methods, internal standards were included with the samples and calibration curves were calculated using least squares with a spreadsheet program. As a further check, liquid chromatography was used to analyze the samples for benzene and toluene.

Key concepts: Gasoline, Chemistry, Benzene, Electron ionization, Analytical Chemistry (journal), Gas chromatography, Toluene, Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of gasoline for aromatic hydrocarbons by GC/MS and by low-EV-HR/MS — Research Paper | ScholarLens