Three-dimensional double-echo steady-state (3D-DESS) magnetic resonance imaging of the knee: establishment of flip angles for evaluation of cartilage at 1.5 T and 3.0 T
Susumu Moriya, Yukio Miki, Yukako Matsuno, Masayo Okada
Abstract
Susumu Moriya, Yukio Miki, Yukako Matsuno, Masayo Okada
Abstract
BACKGROUND: The effect of flip angle (FA) on synovial fluid and cartilage signal and on image contrast using three-dimensional double-echo steady-state (3D-DESS) sequence have only been performed with 1.0-T but not with 1.5-T or 3.0-T scanners. PURPOSE: To identify the FA that gives the maximum synovial fluid and cartilage values, and to identify the FA at which maximum values of synovial fluid-cartilage contrast-to-noise ratio (CNR) in 3D-DESS sequences when 1.5-T and 3.0-T scanners are used. MATERIAL AND METHODS: Using 3D-DESS with water-excitation pulse, mid-sagittal plane images of the knees of 10 healthy volunteers (5 men, 5 women; age range, 21-42 years) were obtained with FA varying from 10° to 90°. Synovial fluid signals, cartilage signals, and background were measured at each FA, and the FA that gave the highest synovial fluid and cartilage values was obtained. Synovial fluid-cartilage CNR was also calculated, and the FA that gave the largest CNR was obtained. RESULTS: At 1.5 T, the maximum synovial fluid signal was at FA 90°, and the maximum cartilage signal was at FA 30°. Synovial fluid-cartilage CNR was highest at FA 90° (P < 0.05). At 3.0 T, the maximum synovial fluid signal was at FA 90°, and the maximum cartilage signal was at FA 20°. Synovial fluid-cartilage CNR was highest at FA 90° (P < 0.05). CONCLUSION: In order to improve the visibility of cartilage itself, FA settings of 30° at 1.5 T and 20° at 3.0 T are apparently ideal. For observing the cartilage surface, the most effective FA setting is 90° for both 1.5 T and 3.0 T.
OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND: The effect of flip angle (FA) on synovial fluid and cartilage signal and on image contrast using three-dimensional double-echo steady-state (3D-DESS) sequence have only been performed with 1.0-T but not with 1.5-T or 3.0-T scanners. PURPOSE: To identify the FA that gives the maximum synovial fluid and cartilage values, and to identify the FA at which maximum values of synovial fluid-cartilage contrast-to-noise ratio (CNR) in 3D-DESS sequences when 1.5-T and 3.0-T scanners are used. MATERIAL AND METHODS: Using 3D-DESS with water-excitation pulse, mid-sagittal plane images of the knees of 10 healthy volunteers (5 men, 5 women; age range, 21-42 years) were obtained with FA varying from 10° to 90°. Synovial fluid signals, cartilage signals, and background were measured at each FA, and the FA that gave the highest synovial fluid and cartilage values was obtained. Synovial fluid-cartilage CNR was also calculated, and the FA that gave the largest CNR was obtained. RESULTS: At 1.5 T, the maximum synovial fluid signal was at FA 90°, and the maximum cartilage signal was at FA 30°. Synovial fluid-cartilage CNR was highest at FA 90° (P < 0.05). At 3.0 T, the maximum synovial fluid signal was at FA 90°, and the maximum cartilage signal was at FA 20°. Synovial fluid-cartilage CNR was highest at FA 90° (P < 0.05). CONCLUSION: In order to improve the visibility of cartilage itself, FA settings of 30° at 1.5 T and 20° at 3.0 T are apparently ideal. For observing the cartilage surface, the most effective FA setting is 90° for both 1.5 T and 3.0 T.
Key concepts: Cartilage, Synovial fluid, Flip angle, Medicine, Magnetic resonance imaging, Sagittal plane, Nuclear medicine, Osteoarthritis