2005Transactions of the Atomic Energy Society of JapanOpen access

Heat Exchanger Performance in Main Cooling System on High Temperature Test Operation at High Temperature Gas-Cooled Reactor 'HTTR'

Daisuke Tochio, Shigeaki Nakagawa, Takayuki Furusawa

Open full text 3 citations

Abstract

High Temperature Engineering Test Reactor (HTTR) of high temperature gas-cooled reactor at Japan Atomic Energy Research Institute achieved the reactor outlet coolant temperature of 950°C for the first time in the world at Apr. 19, 2004. To remove generated heat at reactor core and to hold reactor inlet coolant temperature as specified temperature, heat exchangers in HTTR main cooling system should have designed heat exchange performance.In this report, heat exchanger performance is evaluated based on measurement data in high temperature test operation. And it is confirmed the adequacy of heat exchanger designing method by comparison of evaluated value with designed value.

Open-access reader

About this research paper

What this paper is about

High Temperature Engineering Test Reactor (HTTR) of high temperature gas-cooled reactor at Japan Atomic Energy Research Institute achieved the reactor outlet coolant temperature of 950°C for the first time in the world at Apr. 19, 2004. To remove generated heat at reactor core and to hold reactor inlet coolant temperature as specified temperature, heat exchangers in HTTR main cooling system should have designed heat exchange performance.In this report, heat exchanger performance is evaluated based on measurement data in high temperature test operation. And it is confirmed the adequacy of heat exchanger designing method by comparison of evaluated value with designed value.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

High Temperature Engineering Test Reactor (HTTR) of high temperature gas-cooled reactor at Japan Atomic Energy Research Institute achieved the reactor outlet coolant temperature of 950°C for the first time in the world at Apr. 19, 2004. To remove generated heat at reactor core and to hold reactor inlet coolant temperature as specified temperature, heat exchangers in HTTR main cooling system should have designed heat exchange performance.In this report, heat exchanger performance is evaluated based on measurement data in high temperature test operation. And it is confirmed the adequacy of heat exchanger designing method by comparison of evaluated value with designed value.

Key concepts: Nuclear engineering, Heat exchanger, Coolant, Materials science, Water cooling, Nuclear reactor, Nuclear reactor core, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Heat Exchanger Performance in Main Cooling System on High Temperature Test Operation at High Temperature Gas-Cooled Reactor 'HTTR' — Research Paper | ScholarLens