1996Journal of Computer Assisted TomographyRequires access

Improving the Diagnostic Accuracy of MR in the Detection of Infraspinatus Tendon Injuries

Stacy Goergen, William G. Bradley, Jerome Liu, Judy K. Tam, M D Dubin, Peter J. Pema, Louis M. Teresi, John E. Jordan, David G. Morrison

Open publisher page 7 citations

Abstract

PURPOSE: Our goal was to determine the accuracy of MRI in the diagnosis of infraspinatus tendon injury and more specifically to determine if the antero-posterior extent of a rotator cuff tear is predictive of infraspinatus tearing. METHOD: The MR images of 41 shoulders with surgically proven supraspinatus tears at surgery were retrospectively reviewed. The following were assessed for each of the 41 studies: the number of oblique coronal images on which a tendon defect could be seen, the angle subtended by the tear on axial images (the rotator cuff "axial angle"), and the extent of signal abnormality on sagittal images. RESULTS: The rotator cuff axial angle was 75.6 degrees in patients with infraspinatus tendon tears (ITTs) versus 40 degrees in those without ITTs, and this difference was significant (p < 0.001, t = 3.06). The mean number of oblique coronal images (obtained with a 4 mm slice and 1 mm gap) showing signal abnormality was 5.4 in the ITT group versus 2.9 in those without ITTs, and this difference was also significant (p < 0.001, t = 4.45). The mean sagittal extent of the tendon abnormality was 24.6 mm in the ITT group and 11.6 mm in those without ITTs, but the difference was not significant (p > 0.05, t = 1.1364). CONCLUSION: The axial angle and the number of oblique coronal images in which signal abnormality was present were significantly related to a higher incidence of infraspinatus tears.

About this research paper

What this paper is about

PURPOSE: Our goal was to determine the accuracy of MRI in the diagnosis of infraspinatus tendon injury and more specifically to determine if the antero-posterior extent of a rotator cuff tear is predictive of infraspinatus tearing. METHOD: The MR images of 41 shoulders with surgically proven supraspinatus tears at surgery were retrospectively reviewed. The following were assessed for each of the 41 studies: the number of oblique coronal images on which a tendon defect could be seen, the angle subtended by the tear on axial images (the rotator cuff "axial angle"), and the extent of signal abnormality on sagittal images. RESULTS: The rotator cuff axial angle was 75.6 degrees in patients with infraspinatus tendon tears (ITTs) versus 40 degrees in those without ITTs, and this difference was significant (p < 0.001, t = 3.06). The mean number of oblique coronal images (obtained with a 4 mm slice and 1 mm gap) showing signal abnormality was 5.4 in the ITT group versus 2.9 in those without ITTs, and this difference was also significant (p < 0.001, t = 4.45). The mean sagittal extent of the tendon abnormality was 24.6 mm in the ITT group and 11.6 mm in those without ITTs, but the difference was not significant (p > 0.05, t = 1.1364). CONCLUSION: The axial angle and the number of oblique coronal images in which signal abnormality was present were significantly related to a higher incidence of infraspinatus tears.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: Our goal was to determine the accuracy of MRI in the diagnosis of infraspinatus tendon injury and more specifically to determine if the antero-posterior extent of a rotator cuff tear is predictive of infraspinatus tearing. METHOD: The MR images of 41 shoulders with surgically proven supraspinatus tears at surgery were retrospectively reviewed. The following were assessed for each of the 41 studies: the number of oblique coronal images on which a tendon defect could be seen, the angle subtended by the tear on axial images (the rotator cuff "axial angle"), and the extent of signal abnormality on sagittal images. RESULTS: The rotator cuff axial angle was 75.6 degrees in patients with infraspinatus tendon tears (ITTs) versus 40 degrees in those without ITTs, and this difference was significant (p < 0.001, t = 3.06). The mean number of oblique coronal images (obtained with a 4 mm slice and 1 mm gap) showing signal abnormality was 5.4 in the ITT group versus 2.9 in those without ITTs, and this difference was also significant (p < 0.001, t = 4.45). The mean sagittal extent of the tendon abnormality was 24.6 mm in the ITT group and 11.6 mm in those without ITTs, but the difference was not significant (p > 0.05, t = 1.1364). CONCLUSION: The axial angle and the number of oblique coronal images in which signal abnormality was present were significantly related to a higher incidence of infraspinatus tears.

Key concepts: Medicine, Tendon, Radiology, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Improving the Diagnostic Accuracy of MR in the Detection of Infraspinatus Tendon Injuries — Research Paper | ScholarLens