2011HeartOpen access

The study of the relation between different end points of slow atrioventricular nodal pathway ablation and clinical efficiency in patients with atrioventricular nodal reentrant tachycardia (slow-fast kind)

Xie Dong-ming, Zhong Yiming, Wei Liao

Open full text 0 citations

Abstract

Objective The study of the Relation between different end points of slow atrioventricular nodal pathway ablation and clinical efficiency in patients with atrioventricular nodal reentrant tachycardia. Methods 350 patients with atrioventricular nodal re-entrant (AVNRT) were treated with slow atrioventricular nodal pathway ablation in order to observe the effect of endpoint type A (on slow pathway conduction and on inducible AVNRT), B (residual slow pathway conduction but no induciable AVNRT and AVN echo) and C (residual slow pathway conduction and 1–3 AVN echo but no induciable AVNRT). Results (1) End point A 77% (270 case), end point B 16% (59 cases), end point C 7% (21 case). (2) There was improvement of AV conduction in patients with end point type A, but no difference in patients with type B and C before and after slow pathway ablation. (3) all patients were followed up 4±1.5 (0.5–8) years and AVNRT recurrence were the same. Conclusion There was improvement of AV conduction in patients with end point type A, but no difference in patients with type B and C before and after slow pathway ablation. The recurrence rate of AVNRT was same in type A, type B and type C.

Open-access reader

About this research paper

What this paper is about

Objective The study of the Relation between different end points of slow atrioventricular nodal pathway ablation and clinical efficiency in patients with atrioventricular nodal reentrant tachycardia. Methods 350 patients with atrioventricular nodal re-entrant (AVNRT) were treated with slow atrioventricular nodal pathway ablation in order to observe the effect of endpoint type A (on slow pathway conduction and on inducible AVNRT), B (residual slow pathway conduction but no induciable AVNRT and AVN echo) and C (residual slow pathway conduction and 1–3 AVN echo but no induciable AVNRT). Results (1) End point A 77% (270 case), end point B 16% (59 cases), end point C 7% (21 case). (2) There was improvement of AV conduction in patients with end point type A, but no difference in patients with type B and C before and after slow pathway ablation. (3) all patients were followed up 4±1.5 (0.5–8) years and AVNRT recurrence were the same. Conclusion There was improvement of AV conduction in patients with end point type A, but no difference in patients with type B and C before and after slow pathway ablation. The recurrence rate of AVNRT was same in type A, type B and type C.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective The study of the Relation between different end points of slow atrioventricular nodal pathway ablation and clinical efficiency in patients with atrioventricular nodal reentrant tachycardia. Methods 350 patients with atrioventricular nodal re-entrant (AVNRT) were treated with slow atrioventricular nodal pathway ablation in order to observe the effect of endpoint type A (on slow pathway conduction and on inducible AVNRT), B (residual slow pathway conduction but no induciable AVNRT and AVN echo) and C (residual slow pathway conduction and 1–3 AVN echo but no induciable AVNRT). Results (1) End point A 77% (270 case), end point B 16% (59 cases), end point C 7% (21 case). (2) There was improvement of AV conduction in patients with end point type A, but no difference in patients with type B and C before and after slow pathway ablation. (3) all patients were followed up 4±1.5 (0.5–8) years and AVNRT recurrence were the same. Conclusion There was improvement of AV conduction in patients with end point type A, but no difference in patients with type B and C before and after slow pathway ablation. The recurrence rate of AVNRT was same in type A, type B and type C.

Key concepts: Medicine, NODAL, Ablation, Tachycardia, Nodal signaling, Cardiology, Internal medicine, Atrioventricular node

Related papers

Back to paper searchBrowse research topicsOriginal source
The study of the relation between different end points of slow atrioventricular nodal pathway ablation and clinical efficiency in patients with atrioventricular nodal reentrant tachycardia (slow-fast kind) — Research Paper | ScholarLens