2010ACTA PHOTONICA SINICARequires access

Design of an 8 Times Ratio Visible Zoom Optical System

范哲源 FAN Zhe-yuan, 曹剑中 Cao Jianzhong, 屈恩世 Qu Enshi, 杨洪涛 Yang Hong-tao

Open publisher page 2 citations

Abstract

An example of 8× ratio visible zoom system with mechanic compensator was designed.The focal length and angle of vision of the system were 6.5~52 mm and 6.6°~52°,respectively.The modulation transfer function(MTF) is above 0.6 within the whole focal range at spatial frequency of 75 lp/mm,and approaches the diffraction limit.RMS value of spot diameter was investigated.The cam curves after optimization was given.The system has the advantages of simple structure,high image quality,short zoom path and smooth zoom locus etc.

About this research paper

What this paper is about

An example of 8× ratio visible zoom system with mechanic compensator was designed.The focal length and angle of vision of the system were 6.5~52 mm and 6.6°~52°,respectively.The modulation transfer function(MTF) is above 0.6 within the whole focal range at spatial frequency of 75 lp/mm,and approaches the diffraction limit.RMS value of spot diameter was investigated.The cam curves after optimization was given.The system has the advantages of simple structure,high image quality,short zoom path and smooth zoom locus etc.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An example of 8× ratio visible zoom system with mechanic compensator was designed.The focal length and angle of vision of the system were 6.5~52 mm and 6.6°~52°,respectively.The modulation transfer function(MTF) is above 0.6 within the whole focal range at spatial frequency of 75 lp/mm,and approaches the diffraction limit.RMS value of spot diameter was investigated.The cam curves after optimization was given.The system has the advantages of simple structure,high image quality,short zoom path and smooth zoom locus etc.

Key concepts: Zoom, Optical transfer function, Optics, Diffraction, Focal length, Image quality, Spatial frequency, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Design of an 8 Times Ratio Visible Zoom Optical System — Research Paper | ScholarLens