2012Investigative Ophthalmology & Visual ScienceRequires access

Pupillometric Evaluation of the Dynamics of the Pupillary Response to a Brief Light Stimulus in Healthy Subjects

Fion Bremner

Open publisher page 87 citations

Abstract

PURPOSE: To investigate the correlation between measurements of amplitude (A) and peak velocity (V) of constriction in the pupil light reflex of normal subjects, and to determine the effects of stimulus intensity, pupil size, and age on this relationship. METHODS: The pupil response to a variable intensity 1.0 second light stimulus presented under open-loop conditions (Maxwellian optics) was measured using infrared video techniques in 43 healthy subjects aged 20 to 75 years old. RESULTS: In response to the "standard-intensity" light stimulus, mean measurements of A and V were 1.92 mm (SD 0.39) and 5.65 mm/s (SD 1.17), respectively. Over a 4.0 log unit range of stimulus intensities measurements of A and V were seen to co-vary with the data being best fit by the equation V=0.86+2.65A (linear regression coefficient, R = 0.919, P < 0.001). In each subject the regression plot was used to normalize the velocity estimates for A = 1.0 mm; these normalized velocity estimates showed no significant correlation with the starting size of the pupil or the age of the subject. CONCLUSIONS: There is a strong linear correlation between amplitude and peak velocity of constriction for the pupil light reflex in normal subjects. This relationship is unaffected by the stimulus intensity, size of the pupil, or age of the subject. Clinicians and researchers must keep this interdependence in mind when drawing inferences from the observed (or measured) speed of the pupillary constriction to light.

About this research paper

What this paper is about

PURPOSE: To investigate the correlation between measurements of amplitude (A) and peak velocity (V) of constriction in the pupil light reflex of normal subjects, and to determine the effects of stimulus intensity, pupil size, and age on this relationship. METHODS: The pupil response to a variable intensity 1.0 second light stimulus presented under open-loop conditions (Maxwellian optics) was measured using infrared video techniques in 43 healthy subjects aged 20 to 75 years old. RESULTS: In response to the "standard-intensity" light stimulus, mean measurements of A and V were 1.92 mm (SD 0.39) and 5.65 mm/s (SD 1.17), respectively. Over a 4.0 log unit range of stimulus intensities measurements of A and V were seen to co-vary with the data being best fit by the equation V=0.86+2.65A (linear regression coefficient, R = 0.919, P < 0.001). In each subject the regression plot was used to normalize the velocity estimates for A = 1.0 mm; these normalized velocity estimates showed no significant correlation with the starting size of the pupil or the age of the subject. CONCLUSIONS: There is a strong linear correlation between amplitude and peak velocity of constriction for the pupil light reflex in normal subjects. This relationship is unaffected by the stimulus intensity, size of the pupil, or age of the subject. Clinicians and researchers must keep this interdependence in mind when drawing inferences from the observed (or measured) speed of the pupillary constriction to light.

Why it matters

OpenAlex reports 87 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To investigate the correlation between measurements of amplitude (A) and peak velocity (V) of constriction in the pupil light reflex of normal subjects, and to determine the effects of stimulus intensity, pupil size, and age on this relationship. METHODS: The pupil response to a variable intensity 1.0 second light stimulus presented under open-loop conditions (Maxwellian optics) was measured using infrared video techniques in 43 healthy subjects aged 20 to 75 years old. RESULTS: In response to the "standard-intensity" light stimulus, mean measurements of A and V were 1.92 mm (SD 0.39) and 5.65 mm/s (SD 1.17), respectively. Over a 4.0 log unit range of stimulus intensities measurements of A and V were seen to co-vary with the data being best fit by the equation V=0.86+2.65A (linear regression coefficient, R = 0.919, P < 0.001). In each subject the regression plot was used to normalize the velocity estimates for A = 1.0 mm; these normalized velocity estimates showed no significant correlation with the starting size of the pupil or the age of the subject. CONCLUSIONS: There is a strong linear correlation between amplitude and peak velocity of constriction for the pupil light reflex in normal subjects. This relationship is unaffected by the stimulus intensity, size of the pupil, or age of the subject. Clinicians and researchers must keep this interdependence in mind when drawing inferences from the observed (or measured) speed of the pupillary constriction to light.

Key concepts: Pupil, Stimulus (psychology), Pupillary light reflex, Linear regression, Amplitude, Audiology, Light intensity, Constriction

Related papers

Back to paper searchBrowse research topicsOriginal source
Pupillometric Evaluation of the Dynamics of the Pupillary Response to a Brief Light Stimulus in Healthy Subjects — Research Paper | ScholarLens