2007PubMedOpen access

ABRF ESRG 2006 study: Edman sequencing as a method for polypeptide quantitation.

Dan Brune, Brian Hampton, Ryōji Kobayashi, Joseph W. Leone, Klaus D. Linse, Jan Pohl, Richard S. Thoma, Nancy D. Denslow

Open full text 10 citations

Abstract

The Edman Sequencing Research Group (ESRG) designs studies on the use of Edman degradation for protein and peptide analysis. These studies provide a means for participating laboratories to compare their analyses against a benchmark of those from other laboratories that provide this valuable service. The main purpose of the 2006 study was to determine how accurate Edman sequencing is for quantitative analysis of polypeptides. Secondarily, participants were asked to identify a modified amino acid residue, N-epsilon-acetyl lysine [Lys(Ac)], present within one of the peptides. The ESRG 2006 peptide mixture consisted of three synthetic peptides. The Peptide Standards Research Group (PSRG) provided two peptides, with the following sequences: KAQYARSVLLEKDAEPDILELATGYR (peptide B), and RQAKVLLYSGR (peptide C). The third peptide, peptide C*, synthesized and characterized by ESRG, was identical to peptide C but with acetyl lysine in position 4. The mixture consisted of 20% peptide B and 40% each of peptide C and its acetylated form, peptide C*. Participating laboratories were provided with two tubes, each containing 100 picomoles of the peptide mixture (as determined by quantitative amino acid analysis) and were asked to provide amino acid assignments, peak areas, retention times at each cycle, as well as initial and repetitive yield estimates for each peptide in the mixture. Details about instruments and parameters used in the analysis were also collected. Participants in the study with access to a mass spectrometer (MALDI-TOF or ESI) were asked to provide information about the relative peak areas of the peptides in the mixture as a comparison with the peptide quantitation results from Edman sequencing. Positive amino acid assignments were 88% correct for peptide C and 93% correct for peptide B. The absolute initial sequencing yields were an average of 67% for peptide (C+C*) and 65.6 % for peptide B. The relative molar ratios determined by Edman sequencing were an average of 4.27 (expected ratio of 4) for peptides (C+C*)/B, and 1.49 for peptide C*/C (expected ratio of 1); the seemingly high 49% error in quantification of Lys(Ac) in peptide C* can be attributed to commercial unavailability of its PTH standard. These values compare very favorably with the values obtained by mass spectrometry.

About this research paper

What this paper is about

The Edman Sequencing Research Group (ESRG) designs studies on the use of Edman degradation for protein and peptide analysis. These studies provide a means for participating laboratories to compare their analyses against a benchmark of those from other laboratories that provide this valuable service. The main purpose of the 2006 study was to determine how accurate Edman sequencing is for quantitative analysis of polypeptides. Secondarily, participants were asked to identify a modified amino acid residue, N-epsilon-acetyl lysine [Lys(Ac)], present within one of the peptides. The ESRG 2006 peptide mixture consisted of three synthetic peptides. The Peptide Standards Research Group (PSRG) provided two peptides, with the following sequences: KAQYARSVLLEKDAEPDILELATGYR (peptide B), and RQAKVLLYSGR (peptide C). The third peptide, peptide C*, synthesized and characterized by ESRG, was identical to peptide C but with acetyl lysine in position 4. The mixture consisted of 20% peptide B and 40% each of peptide C and its acetylated form, peptide C*. Participating laboratories were provided with two tubes, each containing 100 picomoles of the peptide mixture (as determined by quantitative amino acid analysis) and were asked to provide amino acid assignments, peak areas, retention times at each cycle, as well as initial and repetitive yield estimates for each peptide in the mixture. Details about instruments and parameters used in the analysis were also collected. Participants in the study with access to a mass spectrometer (MALDI-TOF or ESI) were asked to provide information about the relative peak areas of the peptides in the mixture as a comparison with the peptide quantitation results from Edman sequencing. Positive amino acid assignments were 88% correct for peptide C and 93% correct for peptide B. The absolute initial sequencing yields were an average of 67% for peptide (C+C*) and 65.6 % for peptide B. The relative molar ratios determined by Edman sequencing were an average of 4.27 (expected ratio of 4) for peptides (C+C*)/B, and 1.49 for peptide C*/C (expected ratio of 1); the seemingly high 49% error in quantification of Lys(Ac) in peptide C* can be attributed to commercial unavailability of its PTH standard. These values compare very favorably with the values obtained by mass spectrometry.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The Edman Sequencing Research Group (ESRG) designs studies on the use of Edman degradation for protein and peptide analysis. These studies provide a means for participating laboratories to compare their analyses against a benchmark of those from other laboratories that provide this valuable service. The main purpose of the 2006 study was to determine how accurate Edman sequencing is for quantitative analysis of polypeptides. Secondarily, participants were asked to identify a modified amino acid residue, N-epsilon-acetyl lysine [Lys(Ac)], present within one of the peptides. The ESRG 2006 peptide mixture consisted of three synthetic peptides. The Peptide Standards Research Group (PSRG) provided two peptides, with the following sequences: KAQYARSVLLEKDAEPDILELATGYR (peptide B), and RQAKVLLYSGR (peptide C). The third peptide, peptide C*, synthesized and characterized by ESRG, was identical to peptide C but with acetyl lysine in position 4. The mixture consisted of 20% peptide B and 40% each of peptide C and its acetylated form, peptide C*. Participating laboratories were provided with two tubes, each containing 100 picomoles of the peptide mixture (as determined by quantitative amino acid analysis) and were asked to provide amino acid assignments, peak areas, retention times at each cycle, as well as initial and repetitive yield estimates for each peptide in the mixture. Details about instruments and parameters used in the analysis were also collected. Participants in the study with access to a mass spectrometer (MALDI-TOF or ESI) were asked to provide information about the relative peak areas of the peptides in the mixture as a comparison with the peptide quantitation results from Edman sequencing. Positive amino acid assignments were 88% correct for peptide C and 93% correct for peptide B. The absolute initial sequencing yields were an average of 67% for peptide (C+C*) and 65.6 % for peptide B. The relative molar ratios determined by Edman sequencing were an average of 4.27 (expected ratio of 4) for peptides (C+C*)/B, and 1.49 for peptide C*/C (expected ratio of 1); the seemingly high 49% error in quantification of Lys(Ac) in peptide C* can be attributed to commercial unavailability of its PTH standard. These values compare very favorably with the values obtained by mass spectrometry.

Key concepts: Edman degradation, Peptide, Peptide sequence, Amino acid, Lysine, Chromatography, Residue (chemistry), Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
ABRF ESRG 2006 study: Edman sequencing as a method for polypeptide quantitation. — Research Paper | ScholarLens