2015International Journal of Advances in Engineering & TechnologyRequires access

Tuning of a First-Order Lag-Lead Compensator used with a Very Slow Second-Order Process

Galal Ali Hassaan

Open publisher page 2 citations

Abstract

Lag-lead compensators are well known in automatic control engineering. They have 3 or 4 parameters to be adjusted (tuned) for proper operation depending on the compensator order. The frequency response of the control system or the root locus plot are traditionally used to tune the compensator in a lengthy procedure. A selected very slow second-order process has a time response to a unit step input of 150 seconds settling time is controlled using a first-order lag-lead compensator (through simulation). The lag-lead compensator is tuned by minimizing the sum of square of errors of the control system using MATLAB. Four functional constrains are used to control the performance of the lag-lead compensated control system. The result was reducing the settling time to only 0.666 seconds. The steady-state characteristics of closed-loop control system using the first-order lag-lead compensator were excellent. It was possible reduce the steady-state error to less than 0.01 using the tuned first-order lag-lead compensator.

About this research paper

What this paper is about

Lag-lead compensators are well known in automatic control engineering. They have 3 or 4 parameters to be adjusted (tuned) for proper operation depending on the compensator order. The frequency response of the control system or the root locus plot are traditionally used to tune the compensator in a lengthy procedure. A selected very slow second-order process has a time response to a unit step input of 150 seconds settling time is controlled using a first-order lag-lead compensator (through simulation). The lag-lead compensator is tuned by minimizing the sum of square of errors of the control system using MATLAB. Four functional constrains are used to control the performance of the lag-lead compensated control system. The result was reducing the settling time to only 0.666 seconds. The steady-state characteristics of closed-loop control system using the first-order lag-lead compensator were excellent. It was possible reduce the steady-state error to less than 0.01 using the tuned first-order lag-lead compensator.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Lag-lead compensators are well known in automatic control engineering. They have 3 or 4 parameters to be adjusted (tuned) for proper operation depending on the compensator order. The frequency response of the control system or the root locus plot are traditionally used to tune the compensator in a lengthy procedure. A selected very slow second-order process has a time response to a unit step input of 150 seconds settling time is controlled using a first-order lag-lead compensator (through simulation). The lag-lead compensator is tuned by minimizing the sum of square of errors of the control system using MATLAB. Four functional constrains are used to control the performance of the lag-lead compensated control system. The result was reducing the settling time to only 0.666 seconds. The steady-state characteristics of closed-loop control system using the first-order lag-lead compensator were excellent. It was possible reduce the steady-state error to less than 0.01 using the tuned first-order lag-lead compensator.

Key concepts: Lead–lag compensator, Lag, Order (exchange), Lead (geology), Process (computing), Control theory (sociology), Computer science, Economics