Effects of Extreme Tonotopic Mismatches Between Bilateral Cochlear Implants on Electric Pitch Perception: A Case Study
Lina A. J. Reiss, Mary W. Lowder, Sue A. Karsten, Christopher W. Turner, Bruce J. Gantz
Abstract
Lina A. J. Reiss, Mary W. Lowder, Sue A. Karsten, Christopher W. Turner, Bruce J. Gantz
Abstract
In Brief Objectives: Recent studies suggest that pitch perceived through cochlear implants (CIs) changes with experience to minimize spectral mismatches between electric and acoustic hearing. This study aimed to test whether perceived spectral mismatches are similarly minimized between two electric inputs. Design: Pitch perception was studied in a subject with a 10-mm CI in one ear and a 24-mm CI in the other ear. Both processors were programmed to allocate information from the same frequency range of 188–7938 Hz, despite the large differences in putative insertion depth and stimulated cochlear locations between the CIs. Results: After 2 and 3 years of experience, pitch-matched electrode pairs between CIs were aligned closer to the processor-provided frequencies than to cochlear position. Conclusions: Pitch perception may have adapted to reduce perceived spectral discrepancies between bilateral CI inputs, despite 2–3 octave differences in tonotopic mapping. Pitch perception was studied in a subject with a 10-mm cochlear implant (CI) in one ear and a 24-mm CI in the other ear. Both processors were programmed to allocate information from the same frequency range of 188 to 7938 Hz, despite the large differences in putative insertion depth and stimulated cochlear locations between the CIs. After 2 and 3 yrs of experience, pitch-matched electrode pairs between CIs were aligned closer to the processor-provided frequencies than to cochlear position. This finding suggests that pitch perception may have adapted to reduce perceived spectral discrepancies between bilateral CI inputs, despite 2- to 3-octave differences in tonotopic mapping.
OpenAlex reports 39 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In Brief Objectives: Recent studies suggest that pitch perceived through cochlear implants (CIs) changes with experience to minimize spectral mismatches between electric and acoustic hearing. This study aimed to test whether perceived spectral mismatches are similarly minimized between two electric inputs. Design: Pitch perception was studied in a subject with a 10-mm CI in one ear and a 24-mm CI in the other ear. Both processors were programmed to allocate information from the same frequency range of 188–7938 Hz, despite the large differences in putative insertion depth and stimulated cochlear locations between the CIs. Results: After 2 and 3 years of experience, pitch-matched electrode pairs between CIs were aligned closer to the processor-provided frequencies than to cochlear position. Conclusions: Pitch perception may have adapted to reduce perceived spectral discrepancies between bilateral CI inputs, despite 2–3 octave differences in tonotopic mapping. Pitch perception was studied in a subject with a 10-mm cochlear implant (CI) in one ear and a 24-mm CI in the other ear. Both processors were programmed to allocate information from the same frequency range of 188 to 7938 Hz, despite the large differences in putative insertion depth and stimulated cochlear locations between the CIs. After 2 and 3 yrs of experience, pitch-matched electrode pairs between CIs were aligned closer to the processor-provided frequencies than to cochlear position. This finding suggests that pitch perception may have adapted to reduce perceived spectral discrepancies between bilateral CI inputs, despite 2- to 3-octave differences in tonotopic mapping.
Key concepts: Tonotopy, Cochlear implant, Audiology, Octave (electronics), Pitch perception, Pitch (Music), Perception, Speech perception