2014Advances in ResearchOpen access

Effect of Distributor Plate Configuration on Pressure Drop in a Bubbling Fluidized Bed Reactor

A. Ghaly, A. Ergüdenler, V. Ramakrishnan

Open full text 11 citations

Abstract

Aim: To study the effects of distributor plate shape and conical angle on the pressure drop were studied in a pilot scale fluidized bed system.Methodology: Five distributor plates (flat, concave with 5°, concave with 10°, convex with 5° and convex with 10°) were used in the study.The system was tested at two levels of sand particle size (a fine sand of 198 µm and coarse sand of 536 µm), various bed heights (0.5 D, 1.0 D, 1.5 D and 2.0 Dcm) and various fluidization velocities (1.25, 1.50, 1.75 and 2.00 U mf ).Results: The pressure drop was affected by the shape and the conical angle of distributor plate, sand particle size and bed height.Less than theoretical values of the pressure drop were observed with the 10° concave distributor plate at lower fluidizing gas velocities for all bed heights.A decrease in the angle of convex and an increase in the angle of concave resulted in a decreased pressure drop.Greater values of pressure drop were obtained with larger sand particles than those obtained with small sand particles at all fluidizing velocities and bed heights.For all distributor Original Research Articleplates, increasing the bed height increased the pressure drop but decreased the ratio of pressure drop across the distributor to the pressure drop across the bed (∆ PD /∆ PB ).There was no variation in the pressure drop in the freeboard.Conclusion: Fluidizing gas velocities higher than 1.25U mf should be used to for a better fluidization, improved mixing and avoiding slugging of the bed.

Open-access reader

About this research paper

What this paper is about

Aim: To study the effects of distributor plate shape and conical angle on the pressure drop were studied in a pilot scale fluidized bed system.Methodology: Five distributor plates (flat, concave with 5°, concave with 10°, convex with 5° and convex with 10°) were used in the study.The system was tested at two levels of sand particle size (a fine sand of 198 µm and coarse sand of 536 µm), various bed heights (0.5 D, 1.0 D, 1.5 D and 2.0 Dcm) and various fluidization velocities (1.25, 1.50, 1.75 and 2.00 U mf ).Results: The pressure drop was affected by the shape and the conical angle of distributor plate, sand particle size and bed height.Less than theoretical values of the pressure drop were observed with the 10° concave distributor plate at lower fluidizing gas velocities for all bed heights.A decrease in the angle of convex and an increase in the angle of concave resulted in a decreased pressure drop.Greater values of pressure drop were obtained with larger sand particles than those obtained with small sand particles at all fluidizing velocities and bed heights.For all distributor Original Research Articleplates, increasing the bed height increased the pressure drop but decreased the ratio of pressure drop across the distributor to the pressure drop across the bed (∆ PD /∆ PB ).There was no variation in the pressure drop in the freeboard.Conclusion: Fluidizing gas velocities higher than 1.25U mf should be used to for a better fluidization, improved mixing and avoiding slugging of the bed.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aim: To study the effects of distributor plate shape and conical angle on the pressure drop were studied in a pilot scale fluidized bed system.Methodology: Five distributor plates (flat, concave with 5°, concave with 10°, convex with 5° and convex with 10°) were used in the study.The system was tested at two levels of sand particle size (a fine sand of 198 µm and coarse sand of 536 µm), various bed heights (0.5 D, 1.0 D, 1.5 D and 2.0 Dcm) and various fluidization velocities (1.25, 1.50, 1.75 and 2.00 U mf ).Results: The pressure drop was affected by the shape and the conical angle of distributor plate, sand particle size and bed height.Less than theoretical values of the pressure drop were observed with the 10° concave distributor plate at lower fluidizing gas velocities for all bed heights.A decrease in the angle of convex and an increase in the angle of concave resulted in a decreased pressure drop.Greater values of pressure drop were obtained with larger sand particles than those obtained with small sand particles at all fluidizing velocities and bed heights.For all distributor Original Research Articleplates, increasing the bed height increased the pressure drop but decreased the ratio of pressure drop across the distributor to the pressure drop across the bed (∆ PD /∆ PB ).There was no variation in the pressure drop in the freeboard.Conclusion: Fluidizing gas velocities higher than 1.25U mf should be used to for a better fluidization, improved mixing and avoiding slugging of the bed.

Key concepts: Distributor, Pressure drop, Fluidized bed, Fluidization, Materials science, Mechanics, Drop (telecommunication), Nuclear engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of Distributor Plate Configuration on Pressure Drop in a Bubbling Fluidized Bed Reactor — Research Paper | ScholarLens