2012•Analytical ChemistryRequires access

Microfluidic Cytometer for the Characterization of Cell Lysis

Jeffrey R. SooHoo, Joshua K. Herr, J. Michael Ramsey, Glenn M. Walker

Open publisher page 14 citations

Abstract

Blood cytometry and intercellular analysis typically requires lysis as a preparatory step, which can alter the results of downstream analyses. We fabricated a microfluidic cytometer to characterize erythrocyte lysis kinetics. Forward light scatter from erythrocytes was used for enumeration at specific locations on a microfluidic chip. Diffusive transport coupled with laminar flow was used to control the concentration and exposure time of the lysis reagent Zap-OGLOBIN II to erythrocytes. Standard clinical practice is to expose erythrocytes to lysis reagent for 10 min. Under optimum conditions, we achieved complete erythrocyte lysis of a blood sample in 0.7 s. A maximum lysis reaction rate of 1.55 s(-1) was extrapolated from the data. Lysis began after 0.2 s and could be initiated with a lysis reagent concentration of 1.0% (68.5 mM). An equation that related lysis reagent concentration, [A], to erythrocyte lysis, [B], was determined to be [B] = -0.77[A](0.29)t.

About this research paper

What this paper is about

Blood cytometry and intercellular analysis typically requires lysis as a preparatory step, which can alter the results of downstream analyses. We fabricated a microfluidic cytometer to characterize erythrocyte lysis kinetics. Forward light scatter from erythrocytes was used for enumeration at specific locations on a microfluidic chip. Diffusive transport coupled with laminar flow was used to control the concentration and exposure time of the lysis reagent Zap-OGLOBIN II to erythrocytes. Standard clinical practice is to expose erythrocytes to lysis reagent for 10 min. Under optimum conditions, we achieved complete erythrocyte lysis of a blood sample in 0.7 s. A maximum lysis reaction rate of 1.55 s(-1) was extrapolated from the data. Lysis began after 0.2 s and could be initiated with a lysis reagent concentration of 1.0% (68.5 mM). An equation that related lysis reagent concentration, [A], to erythrocyte lysis, [B], was determined to be [B] = -0.77[A](0.29)t.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Blood cytometry and intercellular analysis typically requires lysis as a preparatory step, which can alter the results of downstream analyses. We fabricated a microfluidic cytometer to characterize erythrocyte lysis kinetics. Forward light scatter from erythrocytes was used for enumeration at specific locations on a microfluidic chip. Diffusive transport coupled with laminar flow was used to control the concentration and exposure time of the lysis reagent Zap-OGLOBIN II to erythrocytes. Standard clinical practice is to expose erythrocytes to lysis reagent for 10 min. Under optimum conditions, we achieved complete erythrocyte lysis of a blood sample in 0.7 s. A maximum lysis reaction rate of 1.55 s(-1) was extrapolated from the data. Lysis began after 0.2 s and could be initiated with a lysis reagent concentration of 1.0% (68.5 mM). An equation that related lysis reagent concentration, [A], to erythrocyte lysis, [B], was determined to be [B] = -0.77[A](0.29)t.

Key concepts: Lysis, Reagent, Chemistry, Microfluidics, Red blood cell, Lysis buffer, Chromatography, Flow cytometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Microfluidic Cytometer for the Characterization of Cell Lysis — Research Paper | ScholarLens