2014EndoscopyOpen access

Endoscopic management of an esophagopleural fistula resulting from a gunshot wound

Shashank Garg, Mark R. Katlic, Sudhir Dutta

Open full text 1 citations

Abstract

A 36-year-old man presented to the emergency department with a gunshot injury to his neck. He was intubated and taken to the operating room. As his neck was being dissected, an air leak in the trachea, indicative of a direct injury from the gunshot wound, was detected. This was repaired successfully. No damage to the esophagus was seen during an intraoperative esophagoscopy. A Gastrografin esophagogram was done on the sixth postoperative day, before the patient recommenced oral intake, and did not show any esophageal leak ([ Fig. 1 ]). However, within 1 day of his restarting oral intake, the patient developed a new onset leukocytosis. A barium swallow on the seventh postoperative day showed an esophageal fistula draining into the left pleural space ( [ Fig. 2 ]). This fistulous track was not seen on the preoperative esophagoscopy and it most likely developed postoperatively. Fig. 1 Gastrografin esophagogram 6 days after surgery to the neck for a gunshot wound showing no evidence of an esophageal leak. Fig. 2 Barium swallow performed the following day showing a well formed fistulous track from the esophagus to the left pleural space (arrow). The fistulous track was well formed but it was considered to be very likely to close with nonoperative management. Therefore, an upper gastrointestinal endoscopy was performed which showed an 8-mm esophageal fistula, 17 cm from the incisors, that was seen as soon as the upper esophageal sphincter was traversed with the endoscope ([ Fig. 3 a ]). The fistula was closed using three endoscopic Hemoclips (Wilson-Cook Medical Inc., Winston-Salem, North Carolina, USA) ([ Fig. 3 b ]). A follow-up barium swallow 3 days later showed complete closure of the esophagopleural fistula ([ Fig. 4 ]). The patient tolerated his oral diet well and he was discharged 12 days after the endoscopic closure. Fig. 3 Views during esophagoscopy showing: a the opening of the esophageal fistula (arrow); b endoclips placed to close the esophageal fistula (arrows). Fig. 4 Barium swallow 3 days after the endoscopic closure of the fistula showing no esophageal leak and the endoclips visible within the esophageal lumen (arrow). This case illustrates some unique clinical features. First, the fistula formation was thought to be secondary to thermal injury to the esophagus from the bullet fragments. The Gastrografin study failed to demonstrate the presence of the fistulous track, although Gastrografin studies are associated with a false-negative rate of up to 22 % for the detection of traumatic esophageal fistulas [ 1 ]. Finally, the fistula size was small, which therefore permitted closure with endoclips. In conclusion, esophageal fistulas can form late after a traumatic injury in the surrounding area and endoscopic closure of such fistulas is possible in carefully selected patients using commonly available endoclips. Endoscopy_UCTN_Code_CCL_1AB_2AC_3AH

Open-access reader

About this research paper

What this paper is about

A 36-year-old man presented to the emergency department with a gunshot injury to his neck. He was intubated and taken to the operating room. As his neck was being dissected, an air leak in the trachea, indicative of a direct injury from the gunshot wound, was detected. This was repaired successfully. No damage to the esophagus was seen during an intraoperative esophagoscopy. A Gastrografin esophagogram was done on the sixth postoperative day, before the patient recommenced oral intake, and did not show any esophageal leak ([ Fig. 1 ]). However, within 1 day of his restarting oral intake, the patient developed a new onset leukocytosis. A barium swallow on the seventh postoperative day showed an esophageal fistula draining into the left pleural space ( [ Fig. 2 ]). This fistulous track was not seen on the preoperative esophagoscopy and it most likely developed postoperatively. Fig. 1 Gastrografin esophagogram 6 days after surgery to the neck for a gunshot wound showing no evidence of an esophageal leak. Fig. 2 Barium swallow performed the following day showing a well formed fistulous track from the esophagus to the left pleural space (arrow). The fistulous track was well formed but it was considered to be very likely to close with nonoperative management. Therefore, an upper gastrointestinal endoscopy was performed which showed an 8-mm esophageal fistula, 17 cm from the incisors, that was seen as soon as the upper esophageal sphincter was traversed with the endoscope ([ Fig. 3 a ]). The fistula was closed using three endoscopic Hemoclips (Wilson-Cook Medical Inc., Winston-Salem, North Carolina, USA) ([ Fig. 3 b ]). A follow-up barium swallow 3 days later showed complete closure of the esophagopleural fistula ([ Fig. 4 ]). The patient tolerated his oral diet well and he was discharged 12 days after the endoscopic closure. Fig. 3 Views during esophagoscopy showing: a the opening of the esophageal fistula (arrow); b endoclips placed to close the esophageal fistula (arrows). Fig. 4 Barium swallow 3 days after the endoscopic closure of the fistula showing no esophageal leak and the endoclips visible within the esophageal lumen (arrow). This case illustrates some unique clinical features. First, the fistula formation was thought to be secondary to thermal injury to the esophagus from the bullet fragments. The Gastrografin study failed to demonstrate the presence of the fistulous track, although Gastrografin studies are associated with a false-negative rate of up to 22 % for the detection of traumatic esophageal fistulas [ 1 ]. Finally, the fistula size was small, which therefore permitted closure with endoclips. In conclusion, esophageal fistulas can form late after a traumatic injury in the surrounding area and endoscopic closure of such fistulas is possible in carefully selected patients using commonly available endoclips. Endoscopy_UCTN_Code_CCL_1AB_2AC_3AH

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A 36-year-old man presented to the emergency department with a gunshot injury to his neck. He was intubated and taken to the operating room. As his neck was being dissected, an air leak in the trachea, indicative of a direct injury from the gunshot wound, was detected. This was repaired successfully. No damage to the esophagus was seen during an intraoperative esophagoscopy. A Gastrografin esophagogram was done on the sixth postoperative day, before the patient recommenced oral intake, and did not show any esophageal leak ([ Fig. 1 ]). However, within 1 day of his restarting oral intake, the patient developed a new onset leukocytosis. A barium swallow on the seventh postoperative day showed an esophageal fistula draining into the left pleural space ( [ Fig. 2 ]). This fistulous track was not seen on the preoperative esophagoscopy and it most likely developed postoperatively. Fig. 1 Gastrografin esophagogram 6 days after surgery to the neck for a gunshot wound showing no evidence of an esophageal leak. Fig. 2 Barium swallow performed the following day showing a well formed fistulous track from the esophagus to the left pleural space (arrow). The fistulous track was well formed but it was considered to be very likely to close with nonoperative management. Therefore, an upper gastrointestinal endoscopy was performed which showed an 8-mm esophageal fistula, 17 cm from the incisors, that was seen as soon as the upper esophageal sphincter was traversed with the endoscope ([ Fig. 3 a ]). The fistula was closed using three endoscopic Hemoclips (Wilson-Cook Medical Inc., Winston-Salem, North Carolina, USA) ([ Fig. 3 b ]). A follow-up barium swallow 3 days later showed complete closure of the esophagopleural fistula ([ Fig. 4 ]). The patient tolerated his oral diet well and he was discharged 12 days after the endoscopic closure. Fig. 3 Views during esophagoscopy showing: a the opening of the esophageal fistula (arrow); b endoclips placed to close the esophageal fistula (arrows). Fig. 4 Barium swallow 3 days after the endoscopic closure of the fistula showing no esophageal leak and the endoclips visible within the esophageal lumen (arrow). This case illustrates some unique clinical features. First, the fistula formation was thought to be secondary to thermal injury to the esophagus from the bullet fragments. The Gastrografin study failed to demonstrate the presence of the fistulous track, although Gastrografin studies are associated with a false-negative rate of up to 22 % for the detection of traumatic esophageal fistulas [ 1 ]. Finally, the fistula size was small, which therefore permitted closure with endoclips. In conclusion, esophageal fistulas can form late after a traumatic injury in the surrounding area and endoscopic closure of such fistulas is possible in carefully selected patients using commonly available endoclips. Endoscopy_UCTN_Code_CCL_1AB_2AC_3AH

Key concepts: Medicine, Gunshot wound, GUNSHOT INJURY, Surgery, Esophagus, Fistula, Leak, Neck injury

Related papers

Back to paper searchBrowse research topicsOriginal source
Endoscopic management of an esophagopleural fistula resulting from a gunshot wound — Research Paper | ScholarLens