1992Journal of Pediatric OrthopaedicsRequires access

Single Versus Double Screw Fixation for Treatment of Slipped Capital Femoral Epiphysis

Lori A. Karol, Robert Doane, Samuel F. Cornicelli, Paul A. Zak, Roger C. Haut, Arthur Manoli

Open publisher page 97 citations

Abstract

Slipped capital femoral epiphyses (SCFE) were created in 10 pair of bovine femurs. Each pair was pinned with a single screw on one side and two screws contralaterally. The specimens were reloaded to failure. Double pin fixation yielded only a 33% increase in stiffness as compared with single pin fixation. Resistance to further slip was not proportional to screw number. The stiffness of neither double nor single screw fixation approximated that of the intact physis. Single screw fixation in slipped epiphyses is recommended because the small gains in stiffness with a second screw do not offset the risk of complications.

About this research paper

What this paper is about

Slipped capital femoral epiphyses (SCFE) were created in 10 pair of bovine femurs. Each pair was pinned with a single screw on one side and two screws contralaterally. The specimens were reloaded to failure. Double pin fixation yielded only a 33% increase in stiffness as compared with single pin fixation. Resistance to further slip was not proportional to screw number. The stiffness of neither double nor single screw fixation approximated that of the intact physis. Single screw fixation in slipped epiphyses is recommended because the small gains in stiffness with a second screw do not offset the risk of complications.

Why it matters

OpenAlex reports 97 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Slipped capital femoral epiphyses (SCFE) were created in 10 pair of bovine femurs. Each pair was pinned with a single screw on one side and two screws contralaterally. The specimens were reloaded to failure. Double pin fixation yielded only a 33% increase in stiffness as compared with single pin fixation. Resistance to further slip was not proportional to screw number. The stiffness of neither double nor single screw fixation approximated that of the intact physis. Single screw fixation in slipped epiphyses is recommended because the small gains in stiffness with a second screw do not offset the risk of complications.

Key concepts: Slipped capital femoral epiphysis, Physis, Medicine, Epiphysiolysis, Fixation (population genetics), Stiffness, Orthodontics, Orthopedic surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Single Versus Double Screw Fixation for Treatment of Slipped Capital Femoral Epiphysis — Research Paper | ScholarLens