Mass Sensitivity Calculation of the Protein Layer Using Love Wave SAW Biosensor
Sang‐Dae Lee, Ki Bok Kim, Yong Il Kim
Abstract
Sang‐Dae Lee, Ki Bok Kim, Yong Il Kim
Abstract
Love waves, a variety of surface acoustic waves (SAWs), can be used to detect very small biological surface interactions and so have a wide range of potential applications. To demonstrate the practicality of a Love wave SAW biosensor, we fabricated a 155-MHz Love wave SAW biosensor and compared it with a commercial surface Plasmon resonance (SPR) using glycerol-water solution with known densities and viscosities to calibrate the response signals of the biosensors. And the mass per unit area of anti-mouse IgG bound with protein G onto the sensitive layer of the biosensor was calculated on the basis of the calibration result. The sensitivity of the Love wave SAW biosensor was the same as or greater than that of the SPR biosensor. Furthermore, the Love wave SAW biosensor was capable of measuring a much wider range of viscosities than the SPR biosensor. Although the operating principle of the Love wave SAW biosensor is completely different from that of the SPR biosensor, the subtle changes in the viscoelastic properties of the biological layer that accompany biological binding reactions on the sensitive layer can be monitored and measured in the same ways as with the SPR biosensor.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Love waves, a variety of surface acoustic waves (SAWs), can be used to detect very small biological surface interactions and so have a wide range of potential applications. To demonstrate the practicality of a Love wave SAW biosensor, we fabricated a 155-MHz Love wave SAW biosensor and compared it with a commercial surface Plasmon resonance (SPR) using glycerol-water solution with known densities and viscosities to calibrate the response signals of the biosensors. And the mass per unit area of anti-mouse IgG bound with protein G onto the sensitive layer of the biosensor was calculated on the basis of the calibration result. The sensitivity of the Love wave SAW biosensor was the same as or greater than that of the SPR biosensor. Furthermore, the Love wave SAW biosensor was capable of measuring a much wider range of viscosities than the SPR biosensor. Although the operating principle of the Love wave SAW biosensor is completely different from that of the SPR biosensor, the subtle changes in the viscoelastic properties of the biological layer that accompany biological binding reactions on the sensitive layer can be monitored and measured in the same ways as with the SPR biosensor.
Key concepts: Biosensor, Surface plasmon resonance, Materials science, Surface acoustic wave, Love wave, Sensitivity (control systems), Layer (electronics), Analytical Chemistry (journal)