2013OrthopedicsRequires access

Prevention of Cortical Breach During Placement of an Antegrade Intramedullary Femoral Nail

John Alan Scolaro, Christina Endress, Samir Mehta

Open publisher page 16 citations

Abstract

The radius of curvature of femoral intramedullary nails does not match the average radius of curvature of the human femur. Anterior cortical breach of the distal femur during nail placement has been reported in certain fracture patterns, in femora with a smaller radius of curvature, and at the starting point of the nail. The authors describe a novel technique used to prevent anterior cortical disruption of the femur using multiple percutaneously placed Steinmann pins. This technique ensures safe passage of medullary reamers and the femoral nail.

About this research paper

What this paper is about

The radius of curvature of femoral intramedullary nails does not match the average radius of curvature of the human femur. Anterior cortical breach of the distal femur during nail placement has been reported in certain fracture patterns, in femora with a smaller radius of curvature, and at the starting point of the nail. The authors describe a novel technique used to prevent anterior cortical disruption of the femur using multiple percutaneously placed Steinmann pins. This technique ensures safe passage of medullary reamers and the femoral nail.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The radius of curvature of femoral intramedullary nails does not match the average radius of curvature of the human femur. Anterior cortical breach of the distal femur during nail placement has been reported in certain fracture patterns, in femora with a smaller radius of curvature, and at the starting point of the nail. The authors describe a novel technique used to prevent anterior cortical disruption of the femur using multiple percutaneously placed Steinmann pins. This technique ensures safe passage of medullary reamers and the femoral nail.

Key concepts: Intramedullary rod, Medicine, Medullary cavity, Femur, Nail (fastener), Femoral shaft, Anatomy, RADIUS