1989•New England Journal of MedicineRequires access

Detection of Deep-Vein Thrombosis by Real-Time B-Mode Ultrasonography

Anthonie W.A. Lensing, Paolo Prandoni, Dees P. M. Brandjes, Peter M. Huisman, Mario Vigo, G Tomasella, Jelmer Krekt, Jan W. ten Cate, Menno Volkert Huisman, Harry Roger Buller

Open publisher page 879 citations

Abstract

In 220 consecutive outpatients with clinically suspected deep-vein thrombosis of the leg, we compared contrast venography with real-time B-mode ultrasonography, using the single criterion of vein compressibility with the ultrasound transducer probe. The common femoral and popliteal veins were evaluated for full compressibility (no thrombosis) and noncompressibility (thrombosis). Both veins were fully compressible in 142 of the 143 patients with normal venograms (specificity, 99 percent; 95 percent confidence interval, 97 to 100). All 66 patients with proximal-vein thrombosis had noncompressible femoral veins, popliteal veins, or both (sensitivity, 100 percent; 95 percent confidence interval, 95 to 100). For all patients (including 11 with calf-vein thrombi), sensitivity and specificity were 91 (95 percent confidence interval, 82 to 96) and 99 percent, respectively. The sensitivity for isolated calf-vein thrombosis was only 36 percent. The compression ultrasound test was repeated in a subset of 45 consecutive patients by a second examiner, unaware of the results of the first test, whose results agreed in all patients with those of the first examiner (kappa = 1). We conclude that ultrasonography with the single criterion of vein compressibility is a highly accurate, simple, objective, and reproducible noninvasive method for detecting proximal-vein thrombosis in outpatients with clinically suspected deep-venous thrombosis.

About this research paper

What this paper is about

In 220 consecutive outpatients with clinically suspected deep-vein thrombosis of the leg, we compared contrast venography with real-time B-mode ultrasonography, using the single criterion of vein compressibility with the ultrasound transducer probe. The common femoral and popliteal veins were evaluated for full compressibility (no thrombosis) and noncompressibility (thrombosis). Both veins were fully compressible in 142 of the 143 patients with normal venograms (specificity, 99 percent; 95 percent confidence interval, 97 to 100). All 66 patients with proximal-vein thrombosis had noncompressible femoral veins, popliteal veins, or both (sensitivity, 100 percent; 95 percent confidence interval, 95 to 100). For all patients (including 11 with calf-vein thrombi), sensitivity and specificity were 91 (95 percent confidence interval, 82 to 96) and 99 percent, respectively. The sensitivity for isolated calf-vein thrombosis was only 36 percent. The compression ultrasound test was repeated in a subset of 45 consecutive patients by a second examiner, unaware of the results of the first test, whose results agreed in all patients with those of the first examiner (kappa = 1). We conclude that ultrasonography with the single criterion of vein compressibility is a highly accurate, simple, objective, and reproducible noninvasive method for detecting proximal-vein thrombosis in outpatients with clinically suspected deep-venous thrombosis.

Why it matters

OpenAlex reports 879 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In 220 consecutive outpatients with clinically suspected deep-vein thrombosis of the leg, we compared contrast venography with real-time B-mode ultrasonography, using the single criterion of vein compressibility with the ultrasound transducer probe. The common femoral and popliteal veins were evaluated for full compressibility (no thrombosis) and noncompressibility (thrombosis). Both veins were fully compressible in 142 of the 143 patients with normal venograms (specificity, 99 percent; 95 percent confidence interval, 97 to 100). All 66 patients with proximal-vein thrombosis had noncompressible femoral veins, popliteal veins, or both (sensitivity, 100 percent; 95 percent confidence interval, 95 to 100). For all patients (including 11 with calf-vein thrombi), sensitivity and specificity were 91 (95 percent confidence interval, 82 to 96) and 99 percent, respectively. The sensitivity for isolated calf-vein thrombosis was only 36 percent. The compression ultrasound test was repeated in a subset of 45 consecutive patients by a second examiner, unaware of the results of the first test, whose results agreed in all patients with those of the first examiner (kappa = 1). We conclude that ultrasonography with the single criterion of vein compressibility is a highly accurate, simple, objective, and reproducible noninvasive method for detecting proximal-vein thrombosis in outpatients with clinically suspected deep-venous thrombosis.

Key concepts: Medicine, Venography, Thrombosis, Popliteal vein, Deep vein, Confidence interval, Lower limbs venous ultrasonography, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Detection of Deep-Vein Thrombosis by Real-Time B-Mode Ultrasonography — Research Paper | ScholarLens