2012Textile Research JournalRequires access

Experimental determination of bending behavior of multilayered and multidirectionally-stitched E-Glass fabric structures for composites

Kadir Bilişik, Gaye Yolacan

Open publisher page 23 citations

Abstract

The aim of this study was to experimentally determine the bending behavior of developed multilayered multistitched E-Glass preform structures. For this reason, a bending rigidity test instrument based on the cantilever test principle was used. A bending rigidity test was conducted on all developed multilayered multistitched E-Glass preform structures. Yarn linear density and fabric density influenced the bending rigidity of single layer E-Glass fabric. The single layer fabric's bending rigidity depended on the off-axis angle orientations in the fabric plane. On the other hand, the bending rigidity of the multilayered unstitched E-Glass fabric structure depended on the number of fabric layers. The bending rigidities of the multilayered four directional hand and machine stitched E-Glass preform structures were high compared with one and two directional hand and machine stitched E-Glass preform structures. The bending rigidities of all heavy (6 step/cm) machine stitched E-Glass preform structures were high compared with light (2 step/cm) machine and hand (1 step/cm) stitched E-Glass preform structures. In addition, the bending rigidities of all developed multilayered hand and machine stitched E-Glass preform structures were higher than those of unstitched preform structures due to stitching. In addition, the multilayered multistitched preform structures showed a low order of bending curvatures compared with the multilayered unstitched preform structures. The results indicated that the number of stitching directions and stitching steps substantially affected the bending rigidity of the developed preform structures. Stitching yarn type was also a parameter for the bending behaviorof the multistitched preform structures. It was considered that the unstitched fabric structure could be easily formed whereas the directional stitched E-Glass preform structure became stiff and could not be easily formed.

About this research paper

What this paper is about

The aim of this study was to experimentally determine the bending behavior of developed multilayered multistitched E-Glass preform structures. For this reason, a bending rigidity test instrument based on the cantilever test principle was used. A bending rigidity test was conducted on all developed multilayered multistitched E-Glass preform structures. Yarn linear density and fabric density influenced the bending rigidity of single layer E-Glass fabric. The single layer fabric's bending rigidity depended on the off-axis angle orientations in the fabric plane. On the other hand, the bending rigidity of the multilayered unstitched E-Glass fabric structure depended on the number of fabric layers. The bending rigidities of the multilayered four directional hand and machine stitched E-Glass preform structures were high compared with one and two directional hand and machine stitched E-Glass preform structures. The bending rigidities of all heavy (6 step/cm) machine stitched E-Glass preform structures were high compared with light (2 step/cm) machine and hand (1 step/cm) stitched E-Glass preform structures. In addition, the bending rigidities of all developed multilayered hand and machine stitched E-Glass preform structures were higher than those of unstitched preform structures due to stitching. In addition, the multilayered multistitched preform structures showed a low order of bending curvatures compared with the multilayered unstitched preform structures. The results indicated that the number of stitching directions and stitching steps substantially affected the bending rigidity of the developed preform structures. Stitching yarn type was also a parameter for the bending behaviorof the multistitched preform structures. It was considered that the unstitched fabric structure could be easily formed whereas the directional stitched E-Glass preform structure became stiff and could not be easily formed.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this study was to experimentally determine the bending behavior of developed multilayered multistitched E-Glass preform structures. For this reason, a bending rigidity test instrument based on the cantilever test principle was used. A bending rigidity test was conducted on all developed multilayered multistitched E-Glass preform structures. Yarn linear density and fabric density influenced the bending rigidity of single layer E-Glass fabric. The single layer fabric's bending rigidity depended on the off-axis angle orientations in the fabric plane. On the other hand, the bending rigidity of the multilayered unstitched E-Glass fabric structure depended on the number of fabric layers. The bending rigidities of the multilayered four directional hand and machine stitched E-Glass preform structures were high compared with one and two directional hand and machine stitched E-Glass preform structures. The bending rigidities of all heavy (6 step/cm) machine stitched E-Glass preform structures were high compared with light (2 step/cm) machine and hand (1 step/cm) stitched E-Glass preform structures. In addition, the bending rigidities of all developed multilayered hand and machine stitched E-Glass preform structures were higher than those of unstitched preform structures due to stitching. In addition, the multilayered multistitched preform structures showed a low order of bending curvatures compared with the multilayered unstitched preform structures. The results indicated that the number of stitching directions and stitching steps substantially affected the bending rigidity of the developed preform structures. Stitching yarn type was also a parameter for the bending behaviorof the multistitched preform structures. It was considered that the unstitched fabric structure could be easily formed whereas the directional stitched E-Glass preform structure became stiff and could not be easily formed.

Key concepts: Image stitching, Flexural rigidity, Materials science, Composite material, Bending, Rigidity (electromagnetism), Flexural strength, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental determination of bending behavior of multilayered and multidirectionally-stitched E-Glass fabric structures for composites — Research Paper | ScholarLens