2007ECS TransactionsOpen access

Some Milestones in the 50-year History of Electrochemical Oxygen Sensor Development

Lembit Nei

Open full text 11 citations

Abstract

Fifty years have passed since Leland C. Clark proposed the concept of membrane-covered oxygen sensor. The system consists of a two electrode cell with a thin oxygen-permeable membrane separating the electrodes and the electrolyte solution from the analysed media. Oxygen diffuses through the membrane and is reduced at the indicator electrode. This results in current that is proportional to the oxygen concentration in the sample. The Clark Oxygen Sensor has found wide application in medicine, environmental and industrial monitoring. In 1962 Clark and Lyons described the first biosensor. A Clark oxygen sensor was combined with glucose oxidase to detect glucose levels. In spite of the commercial popularity the output currents of Clark-type oxygen sensors are unstable and oxygen analysers need frequent pre-calibration. In 1963 a different oxygen sensor was reported by Mackereth. This design found wide application in water monitoring in the former Soviet Union.

Open-access reader

About this research paper

What this paper is about

Fifty years have passed since Leland C. Clark proposed the concept of membrane-covered oxygen sensor. The system consists of a two electrode cell with a thin oxygen-permeable membrane separating the electrodes and the electrolyte solution from the analysed media. Oxygen diffuses through the membrane and is reduced at the indicator electrode. This results in current that is proportional to the oxygen concentration in the sample. The Clark Oxygen Sensor has found wide application in medicine, environmental and industrial monitoring. In 1962 Clark and Lyons described the first biosensor. A Clark oxygen sensor was combined with glucose oxidase to detect glucose levels. In spite of the commercial popularity the output currents of Clark-type oxygen sensors are unstable and oxygen analysers need frequent pre-calibration. In 1963 a different oxygen sensor was reported by Mackereth. This design found wide application in water monitoring in the former Soviet Union.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fifty years have passed since Leland C. Clark proposed the concept of membrane-covered oxygen sensor. The system consists of a two electrode cell with a thin oxygen-permeable membrane separating the electrodes and the electrolyte solution from the analysed media. Oxygen diffuses through the membrane and is reduced at the indicator electrode. This results in current that is proportional to the oxygen concentration in the sample. The Clark Oxygen Sensor has found wide application in medicine, environmental and industrial monitoring. In 1962 Clark and Lyons described the first biosensor. A Clark oxygen sensor was combined with glucose oxidase to detect glucose levels. In spite of the commercial popularity the output currents of Clark-type oxygen sensors are unstable and oxygen analysers need frequent pre-calibration. In 1963 a different oxygen sensor was reported by Mackereth. This design found wide application in water monitoring in the former Soviet Union.

Key concepts: Oxygen sensor, Oxygen, Clark electrode, Electrolyte, Electrode, Membrane, Oxygen evolution, Electrochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Some Milestones in the 50-year History of Electrochemical Oxygen Sensor Development — Research Paper | ScholarLens