2015Current Opinion in Critical CareOpen access

The promises and problems of transpulmonary pressure measurements in acute respiratory distress syndrome

Sarina K. Sahetya, Roy G. Brower

Open full text 30 citations

Abstract

PURPOSE OF REVIEW: The optimal strategy for assessing and preventing ventilator-induced lung injury in the acute respiratory distress syndrome (ARDS) is controversial. Recent investigative efforts have focused on personalizing ventilator settings to individual respiratory mechanics. This review examines the strengths and weaknesses of using transpulmonary pressure measurements to guide ventilator management in ARDS. RECENT FINDINGS: Recent clinical studies suggest that adjusting ventilator settings based on transpulmonary pressure measurements is feasible, may improve oxygenation, and reduce ventilator-induced lung injury. SUMMARY: The measurement of transpulmonary pressure relies upon esophageal manometry, which requires the acceptance of several assumptions and potential errors. Notably, this includes the ability of localized esophageal pressures to represent global pleural pressure. Recent investigations demonstrated improved oxygenation in ARDS patients when positive end-expiratory pressure was adjusted to target specific end-inspiratory or end-expiratory transpulmonary pressures. However, there are different methods for estimating transpulmonary pressure and different goals for positive end-expiratory pressure titration among recent studies. More research is needed to refine techniques for the estimation and utilization of transpulmonary pressure to guide ventilator settings in ARDS patients.

About this research paper

What this paper is about

PURPOSE OF REVIEW: The optimal strategy for assessing and preventing ventilator-induced lung injury in the acute respiratory distress syndrome (ARDS) is controversial. Recent investigative efforts have focused on personalizing ventilator settings to individual respiratory mechanics. This review examines the strengths and weaknesses of using transpulmonary pressure measurements to guide ventilator management in ARDS. RECENT FINDINGS: Recent clinical studies suggest that adjusting ventilator settings based on transpulmonary pressure measurements is feasible, may improve oxygenation, and reduce ventilator-induced lung injury. SUMMARY: The measurement of transpulmonary pressure relies upon esophageal manometry, which requires the acceptance of several assumptions and potential errors. Notably, this includes the ability of localized esophageal pressures to represent global pleural pressure. Recent investigations demonstrated improved oxygenation in ARDS patients when positive end-expiratory pressure was adjusted to target specific end-inspiratory or end-expiratory transpulmonary pressures. However, there are different methods for estimating transpulmonary pressure and different goals for positive end-expiratory pressure titration among recent studies. More research is needed to refine techniques for the estimation and utilization of transpulmonary pressure to guide ventilator settings in ARDS patients.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE OF REVIEW: The optimal strategy for assessing and preventing ventilator-induced lung injury in the acute respiratory distress syndrome (ARDS) is controversial. Recent investigative efforts have focused on personalizing ventilator settings to individual respiratory mechanics. This review examines the strengths and weaknesses of using transpulmonary pressure measurements to guide ventilator management in ARDS. RECENT FINDINGS: Recent clinical studies suggest that adjusting ventilator settings based on transpulmonary pressure measurements is feasible, may improve oxygenation, and reduce ventilator-induced lung injury. SUMMARY: The measurement of transpulmonary pressure relies upon esophageal manometry, which requires the acceptance of several assumptions and potential errors. Notably, this includes the ability of localized esophageal pressures to represent global pleural pressure. Recent investigations demonstrated improved oxygenation in ARDS patients when positive end-expiratory pressure was adjusted to target specific end-inspiratory or end-expiratory transpulmonary pressures. However, there are different methods for estimating transpulmonary pressure and different goals for positive end-expiratory pressure titration among recent studies. More research is needed to refine techniques for the estimation and utilization of transpulmonary pressure to guide ventilator settings in ARDS patients.

Key concepts: Medicine, Transpulmonary pressure, Acute respiratory distress, Respiratory distress, Intensive care medicine, Anesthesia, Internal medicine, Lung

Related papers

Back to paper searchBrowse research topicsOriginal source
The promises and problems of transpulmonary pressure measurements in acute respiratory distress syndrome — Research Paper | ScholarLens