2013Unpublished venueOpen access

Some Aspects of Sustainable Energy Conversion During Transient Processes in Electric Power Systems Comprising Generator Circuit Breakers

Cornelia Aida Bulucea, Marc A. Rosen, Doru A. Nicola, Nikos E. Mastorakis, Carmen A. Bulucea

Open full text 0 citations

Abstract

This paper is a sequel to a study by the authors of the electric power systems comprising the generator circuit-breakers (GCBs) at power plant generator terminals. A sustainable assessment of the current interruption requirements of a GCB addresses the main stresses on the generator circuit breaker, revealing that the GCB current interruption requirements are significantly higher than for the distribution network circuit breakers. Hence, generator circuit-breakers are subject to unique demanding conditions caused my specific stresses, namely: high asymmetrical fault currents resulting from high d.c. components of the fault current; greater electrical, thermal and mechanical stresses when interrupting longer arcing time faults; and important dielectric stress after the electric arc extinction caused by the transient recovery voltage (TRV). This paper extends other studies of the authors of the energetic and exergetic transformation chain at the interruption current transient process in an electric power system that comprises the generator circuit-breaker, as well as the transient recovery voltage (TRV) which appears after the interruption of a short-circuit fed by the synchronous generator or by the main step-up transformer. For achieving the TRV equivalent configuration the authors applied the method of operational symmetrical components (o.s.c.), and utilized the operational impedances of synchronous generator and of main transformer, depending on the fault location. Modeling the transient recovery voltage of circuits emphasizes aspects with direct implications on commutation equipment. Thus, the o.s.c. method can be applied at the poles of any breaker, for any eliminated fault type, if the network configuration and elements are known. The TRV, which appears after the interruption of a short-circuit fed by the generator, may be considered like an oscillation, where the oscillation factor and the rising rate (RR) of the TRV are established by the electrical machine parameters: resistance, inductance and capacitance. Consequently, modeling of concentrated equivalent parameters of the synchronous generator at perturbations caused by current interruption transient processes is achieved in this study through an approach based on sustainability concepts. These findings allow for simulations of the transient recovery voltage and comparisons with experimental results.

Open-access reader

About this research paper

What this paper is about

This paper is a sequel to a study by the authors of the electric power systems comprising the generator circuit-breakers (GCBs) at power plant generator terminals. A sustainable assessment of the current interruption requirements of a GCB addresses the main stresses on the generator circuit breaker, revealing that the GCB current interruption requirements are significantly higher than for the distribution network circuit breakers. Hence, generator circuit-breakers are subject to unique demanding conditions caused my specific stresses, namely: high asymmetrical fault currents resulting from high d.c. components of the fault current; greater electrical, thermal and mechanical stresses when interrupting longer arcing time faults; and important dielectric stress after the electric arc extinction caused by the transient recovery voltage (TRV). This paper extends other studies of the authors of the energetic and exergetic transformation chain at the interruption current transient process in an electric power system that comprises the generator circuit-breaker, as well as the transient recovery voltage (TRV) which appears after the interruption of a short-circuit fed by the synchronous generator or by the main step-up transformer. For achieving the TRV equivalent configuration the authors applied the method of operational symmetrical components (o.s.c.), and utilized the operational impedances of synchronous generator and of main transformer, depending on the fault location. Modeling the transient recovery voltage of circuits emphasizes aspects with direct implications on commutation equipment. Thus, the o.s.c. method can be applied at the poles of any breaker, for any eliminated fault type, if the network configuration and elements are known. The TRV, which appears after the interruption of a short-circuit fed by the generator, may be considered like an oscillation, where the oscillation factor and the rising rate (RR) of the TRV are established by the electrical machine parameters: resistance, inductance and capacitance. Consequently, modeling of concentrated equivalent parameters of the synchronous generator at perturbations caused by current interruption transient processes is achieved in this study through an approach based on sustainability concepts. These findings allow for simulations of the transient recovery voltage and comparisons with experimental results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper is a sequel to a study by the authors of the electric power systems comprising the generator circuit-breakers (GCBs) at power plant generator terminals. A sustainable assessment of the current interruption requirements of a GCB addresses the main stresses on the generator circuit breaker, revealing that the GCB current interruption requirements are significantly higher than for the distribution network circuit breakers. Hence, generator circuit-breakers are subject to unique demanding conditions caused my specific stresses, namely: high asymmetrical fault currents resulting from high d.c. components of the fault current; greater electrical, thermal and mechanical stresses when interrupting longer arcing time faults; and important dielectric stress after the electric arc extinction caused by the transient recovery voltage (TRV). This paper extends other studies of the authors of the energetic and exergetic transformation chain at the interruption current transient process in an electric power system that comprises the generator circuit-breaker, as well as the transient recovery voltage (TRV) which appears after the interruption of a short-circuit fed by the synchronous generator or by the main step-up transformer. For achieving the TRV equivalent configuration the authors applied the method of operational symmetrical components (o.s.c.), and utilized the operational impedances of synchronous generator and of main transformer, depending on the fault location. Modeling the transient recovery voltage of circuits emphasizes aspects with direct implications on commutation equipment. Thus, the o.s.c. method can be applied at the poles of any breaker, for any eliminated fault type, if the network configuration and elements are known. The TRV, which appears after the interruption of a short-circuit fed by the generator, may be considered like an oscillation, where the oscillation factor and the rising rate (RR) of the TRV are established by the electrical machine parameters: resistance, inductance and capacitance. Consequently, modeling of concentrated equivalent parameters of the synchronous generator at perturbations caused by current interruption transient processes is achieved in this study through an approach based on sustainability concepts. These findings allow for simulations of the transient recovery voltage and comparisons with experimental results.

Key concepts: Transient recovery voltage, Circuit breaker, Electrical engineering, Arc-fault circuit interrupter, Transient (computer programming), Engineering, Prospective short circuit current, Residual-current device

Related papers

Back to paper searchBrowse research topicsOriginal source
Some Aspects of Sustainable Energy Conversion During Transient Processes in Electric Power Systems Comprising Generator Circuit Breakers — Research Paper | ScholarLens