1995Ultrasound QuarterlyRequires access

Ultrasound Safety in Obstetrics

Stanley B Barnett

Open publisher page 8 citations

Abstract

Current developments in international standards and changes in the regulation of medical ultrasound will allow greater control of higher power diagnostic equipment by the ultrasonologist. This brings a responsibility for risk/benefit assessment that requires an understanding of the potential biological effects and the margin of safety for each kind of ultrasound procedure. The development of new, sophisticated diagnostic ultrasound systems has been accompanied by a continuing trend of increasing power outputs. The relaxation of intensity limits for premarket approval by the Food and Drug Administration allows substantially increased intensity of ultrasound to be delivered to the fetus. Modern diagnostic equipment operating at maximum output conditions can produce significant biological effects in mammalian tissues. Substantial increases in temperature have been consistently recorded when the pulsed Doppler ultrasound beam encounters bone in either transcraniator fetal exposures. However, there is no risk of adverse heating effects from ultrasound scanning procedures using simple B-mode. A number of studies have recently reported ultrasound-induced hemorrhagic lesions in tissues of lungs and intestines in mammals following brief exposure to the maximum operating conditions in diagnostic equipment. The effect depends on the presence of a tissue/air interface, thus suggesting it is unlikely to have clinical significance in obstetrical ultrasound examinations. The implications to human health are not fully understood.

About this research paper

What this paper is about

Current developments in international standards and changes in the regulation of medical ultrasound will allow greater control of higher power diagnostic equipment by the ultrasonologist. This brings a responsibility for risk/benefit assessment that requires an understanding of the potential biological effects and the margin of safety for each kind of ultrasound procedure. The development of new, sophisticated diagnostic ultrasound systems has been accompanied by a continuing trend of increasing power outputs. The relaxation of intensity limits for premarket approval by the Food and Drug Administration allows substantially increased intensity of ultrasound to be delivered to the fetus. Modern diagnostic equipment operating at maximum output conditions can produce significant biological effects in mammalian tissues. Substantial increases in temperature have been consistently recorded when the pulsed Doppler ultrasound beam encounters bone in either transcraniator fetal exposures. However, there is no risk of adverse heating effects from ultrasound scanning procedures using simple B-mode. A number of studies have recently reported ultrasound-induced hemorrhagic lesions in tissues of lungs and intestines in mammals following brief exposure to the maximum operating conditions in diagnostic equipment. The effect depends on the presence of a tissue/air interface, thus suggesting it is unlikely to have clinical significance in obstetrical ultrasound examinations. The implications to human health are not fully understood.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Current developments in international standards and changes in the regulation of medical ultrasound will allow greater control of higher power diagnostic equipment by the ultrasonologist. This brings a responsibility for risk/benefit assessment that requires an understanding of the potential biological effects and the margin of safety for each kind of ultrasound procedure. The development of new, sophisticated diagnostic ultrasound systems has been accompanied by a continuing trend of increasing power outputs. The relaxation of intensity limits for premarket approval by the Food and Drug Administration allows substantially increased intensity of ultrasound to be delivered to the fetus. Modern diagnostic equipment operating at maximum output conditions can produce significant biological effects in mammalian tissues. Substantial increases in temperature have been consistently recorded when the pulsed Doppler ultrasound beam encounters bone in either transcraniator fetal exposures. However, there is no risk of adverse heating effects from ultrasound scanning procedures using simple B-mode. A number of studies have recently reported ultrasound-induced hemorrhagic lesions in tissues of lungs and intestines in mammals following brief exposure to the maximum operating conditions in diagnostic equipment. The effect depends on the presence of a tissue/air interface, thus suggesting it is unlikely to have clinical significance in obstetrical ultrasound examinations. The implications to human health are not fully understood.

Key concepts: Medicine, Diagnostic ultrasound, Ultrasound, Radiology, Obstetrics

Related papers

Back to paper searchBrowse research topicsOriginal source
Ultrasound Safety in Obstetrics — Research Paper | ScholarLens