STANDARDIZATION OF PLETHYSMOGRAPHY FOR CLINICAL EXAMINATION OF PERIPHERAL BLOOD CIRCULATION

Fumiaki Motokizawa

Open full text 0 citations

Abstract

As a functional test of blood circulation, either electrocardiography or phonocardiography are essential in daily clinic. On the other hand, a plethysmography is not carried out so frequenfly, because either techniques or interpretation of results in the plethysmography differ with the examiner. In a series of the present experiment, it was planned to standardize the plethysmography as a method for examining a function of peripheral blood circulation. In the first section, experiments were performed to standardize the technique in the plethysmography.1. In a series of the experiment, a reflexion photoelectric plethysmograph was used because it was easy to handle comparing with other methods of the plethysmograph.2. A wave form of a plethysmogram was modified its shape due to a low frequency cut of the plethysmograph. If a time constant of the apparatus is over 2sec, however, the change was insignificant.3. An amplitude as well as a wave form of the plethysmogram was markedly changed due to compression a skin surface beneath the plethysmograph. It was discussed, therefore, that the plethysmograph must be attached to the skin with the pressure by which the plethysmogram showed its maximum amplitude.

Open-access reader

About this research paper

What this paper is about

As a functional test of blood circulation, either electrocardiography or phonocardiography are essential in daily clinic. On the other hand, a plethysmography is not carried out so frequenfly, because either techniques or interpretation of results in the plethysmography differ with the examiner. In a series of the present experiment, it was planned to standardize the plethysmography as a method for examining a function of peripheral blood circulation. In the first section, experiments were performed to standardize the technique in the plethysmography.1. In a series of the experiment, a reflexion photoelectric plethysmograph was used because it was easy to handle comparing with other methods of the plethysmograph.2. A wave form of a plethysmogram was modified its shape due to a low frequency cut of the plethysmograph. If a time constant of the apparatus is over 2sec, however, the change was insignificant.3. An amplitude as well as a wave form of the plethysmogram was markedly changed due to compression a skin surface beneath the plethysmograph. It was discussed, therefore, that the plethysmograph must be attached to the skin with the pressure by which the plethysmogram showed its maximum amplitude.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

As a functional test of blood circulation, either electrocardiography or phonocardiography are essential in daily clinic. On the other hand, a plethysmography is not carried out so frequenfly, because either techniques or interpretation of results in the plethysmography differ with the examiner. In a series of the present experiment, it was planned to standardize the plethysmography as a method for examining a function of peripheral blood circulation. In the first section, experiments were performed to standardize the technique in the plethysmography.1. In a series of the experiment, a reflexion photoelectric plethysmograph was used because it was easy to handle comparing with other methods of the plethysmograph.2. A wave form of a plethysmogram was modified its shape due to a low frequency cut of the plethysmograph. If a time constant of the apparatus is over 2sec, however, the change was insignificant.3. An amplitude as well as a wave form of the plethysmogram was markedly changed due to compression a skin surface beneath the plethysmograph. It was discussed, therefore, that the plethysmograph must be attached to the skin with the pressure by which the plethysmogram showed its maximum amplitude.

Key concepts: Plethysmograph, Medicine, Peripheral, Photoplethysmogram, Blood pressure, Blood circulation, Cardiology, Peripheral blood

Related papers

Back to paper searchBrowse research topicsOriginal source
STANDARDIZATION OF PLETHYSMOGRAPHY FOR CLINICAL EXAMINATION OF PERIPHERAL BLOOD CIRCULATION — Research Paper | ScholarLens