STANDARDIZATION OF PLETHYSMOGRAPHY FOR CLINICAL EXAMINATION OF PERIPHERAL BLOOD CIRCULATION
Fumiaki Motokizawa
Abstract
Open-access reader
Fumiaki Motokizawa
Abstract
Open-access reader
As a functional test of blood circulation, either electrocardiography or phonocardiography are essential in daily clinic. On the other hand, a plethysmography is not carried out so frequenfly, because either techniques or interpretation of results in the plethysmography differ with the examiner. In a series of the present experiment, it was planned to standardize the plethysmography as a method for examining a function of peripheral blood circulation. In the first section, experiments were performed to standardize the technique in the plethysmography.1. In a series of the experiment, a reflexion photoelectric plethysmograph was used because it was easy to handle comparing with other methods of the plethysmograph.2. A wave form of a plethysmogram was modified its shape due to a low frequency cut of the plethysmograph. If a time constant of the apparatus is over 2sec, however, the change was insignificant.3. An amplitude as well as a wave form of the plethysmogram was markedly changed due to compression a skin surface beneath the plethysmograph. It was discussed, therefore, that the plethysmograph must be attached to the skin with the pressure by which the plethysmogram showed its maximum amplitude.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
As a functional test of blood circulation, either electrocardiography or phonocardiography are essential in daily clinic. On the other hand, a plethysmography is not carried out so frequenfly, because either techniques or interpretation of results in the plethysmography differ with the examiner. In a series of the present experiment, it was planned to standardize the plethysmography as a method for examining a function of peripheral blood circulation. In the first section, experiments were performed to standardize the technique in the plethysmography.1. In a series of the experiment, a reflexion photoelectric plethysmograph was used because it was easy to handle comparing with other methods of the plethysmograph.2. A wave form of a plethysmogram was modified its shape due to a low frequency cut of the plethysmograph. If a time constant of the apparatus is over 2sec, however, the change was insignificant.3. An amplitude as well as a wave form of the plethysmogram was markedly changed due to compression a skin surface beneath the plethysmograph. It was discussed, therefore, that the plethysmograph must be attached to the skin with the pressure by which the plethysmogram showed its maximum amplitude.
Key concepts: Plethysmograph, Medicine, Peripheral, Photoplethysmogram, Blood pressure, Blood circulation, Cardiology, Peripheral blood