1996•American Journal of Clinical PathologyOpen access

Sensitivity and Specificity ofthe APC Resistance Assay in Detection of Individuals With Factor V Leiden

James L. Zehnder, Renée C. Benson

Open full text 35 citations

Abstract

Resistance to activated protein C (APC) is the most common cause of familial thrombophilia. The partial thromboplastin time (PTT)-based test for resistance to APC has been widely employed as a screening test for this disorder. However, the utility of this test for screening is not well characterized. More than 90% of patients with resistance to APC have the G1691A mutation in factor V (factor V Leiden). The authors studied the ability of a commercial APC resistance assay to correctly identify the factor V Leiden genotype in 130 individuals. At the recommended assay cut-off value of 2, the sensitivity of the APC resistance assay was 50%, with a specificity of 98%. Increasing the cut-off value increased the sensitivity but decreased the specificity of the test. Receiver operating characteristic (ROC) curve analysis indicated that the test was of intermediate utility. There was considerable overlap in APC ratios in the range of 2 to 3 between subjects with a normal factor V genotype and heterozygotes for factor V Leiden. The authors conclude that the APC resistance assay in its present form is not a useful screening test for factor V Leiden heterozygotes. Until the performance of this assay is improved, patients should have molecular diagnostic testing performed to determine their factor V Leiden status.

Open-access reader

About this research paper

What this paper is about

Resistance to activated protein C (APC) is the most common cause of familial thrombophilia. The partial thromboplastin time (PTT)-based test for resistance to APC has been widely employed as a screening test for this disorder. However, the utility of this test for screening is not well characterized. More than 90% of patients with resistance to APC have the G1691A mutation in factor V (factor V Leiden). The authors studied the ability of a commercial APC resistance assay to correctly identify the factor V Leiden genotype in 130 individuals. At the recommended assay cut-off value of 2, the sensitivity of the APC resistance assay was 50%, with a specificity of 98%. Increasing the cut-off value increased the sensitivity but decreased the specificity of the test. Receiver operating characteristic (ROC) curve analysis indicated that the test was of intermediate utility. There was considerable overlap in APC ratios in the range of 2 to 3 between subjects with a normal factor V genotype and heterozygotes for factor V Leiden. The authors conclude that the APC resistance assay in its present form is not a useful screening test for factor V Leiden heterozygotes. Until the performance of this assay is improved, patients should have molecular diagnostic testing performed to determine their factor V Leiden status.

Why it matters

OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Resistance to activated protein C (APC) is the most common cause of familial thrombophilia. The partial thromboplastin time (PTT)-based test for resistance to APC has been widely employed as a screening test for this disorder. However, the utility of this test for screening is not well characterized. More than 90% of patients with resistance to APC have the G1691A mutation in factor V (factor V Leiden). The authors studied the ability of a commercial APC resistance assay to correctly identify the factor V Leiden genotype in 130 individuals. At the recommended assay cut-off value of 2, the sensitivity of the APC resistance assay was 50%, with a specificity of 98%. Increasing the cut-off value increased the sensitivity but decreased the specificity of the test. Receiver operating characteristic (ROC) curve analysis indicated that the test was of intermediate utility. There was considerable overlap in APC ratios in the range of 2 to 3 between subjects with a normal factor V genotype and heterozygotes for factor V Leiden. The authors conclude that the APC resistance assay in its present form is not a useful screening test for factor V Leiden heterozygotes. Until the performance of this assay is improved, patients should have molecular diagnostic testing performed to determine their factor V Leiden status.

Key concepts: Factor V Leiden, Factor V, Thrombophilia, Activated protein C resistance, Partial thromboplastin time, Medicine, Protein C, Genotype

Related papers

Back to paper searchBrowse research topicsOriginal source
Sensitivity and Specificity ofthe APC Resistance Assay in Detection of Individuals With Factor V Leiden — Research Paper | ScholarLens