2007Unpublished venueRequires access

Combined Turbine Equipment Performance

Anthony E. Butler, Jagadish Nanjappa

Open publisher page 0 citations

Abstract

“Combined Turbine Equipment Performance” represents the combined performance of the Gas Turbine-Generator(s) and the Steam Turbine-Generator(s), while disregarding or holding the performance of the remaining equipment in the Power Plant at its design levels. The lack of established industry standards and methods addressing the manner in which combined turbine equipment performance should be determined has invited confusion and has created opportunities for technical errors to go undetected. This paper presents a method and the supporting theory by which the corrected performance of the turbine-generators within a combined cycle plant can be combined to gauge their combined performance levels for either contractual compliance or for diagnostic purposes. The Combined Turbine Equipment Performance methodology provided in this paper, allows the performance engineer to easily separate the performance contribution of each turbine generator from the overall plant performance. As such, this information becomes a powerful diagnostic tool in circumstances where a reconciliation of overall plant performance is desired. Individual (gas or steam) turbine performance can be determined by conducting a test in accordance with the respective test code (ASME PTC 22 or PTC 6.2). However, each of these test codes corrects the measured equipment performance to fundamentally different reference conditions. Where the gas turbine-generator measured performance is corrected primarily to ambient reference conditions, the steam turbine-generator measured performance is corrected to steam flows and other steam reference conditions. The simple mathematical addition of the corrected performance of each turbine ignores the well-known fact that the steam turbine-generator output in a combined cycle plant is impacted by the gas turbine exhaust conditions, in particular the gas turbine exhaust flow and temperature. The purpose of this paper is to provide a method for the determination of “Combined Turbine Equipment Performance”, review the supporting theory, highlight the assumptions, and develop useful transfer functions for some commonly used combined cycle plant configurations, and bound the uncertainty associated with the methodology.

About this research paper

What this paper is about

“Combined Turbine Equipment Performance” represents the combined performance of the Gas Turbine-Generator(s) and the Steam Turbine-Generator(s), while disregarding or holding the performance of the remaining equipment in the Power Plant at its design levels. The lack of established industry standards and methods addressing the manner in which combined turbine equipment performance should be determined has invited confusion and has created opportunities for technical errors to go undetected. This paper presents a method and the supporting theory by which the corrected performance of the turbine-generators within a combined cycle plant can be combined to gauge their combined performance levels for either contractual compliance or for diagnostic purposes. The Combined Turbine Equipment Performance methodology provided in this paper, allows the performance engineer to easily separate the performance contribution of each turbine generator from the overall plant performance. As such, this information becomes a powerful diagnostic tool in circumstances where a reconciliation of overall plant performance is desired. Individual (gas or steam) turbine performance can be determined by conducting a test in accordance with the respective test code (ASME PTC 22 or PTC 6.2). However, each of these test codes corrects the measured equipment performance to fundamentally different reference conditions. Where the gas turbine-generator measured performance is corrected primarily to ambient reference conditions, the steam turbine-generator measured performance is corrected to steam flows and other steam reference conditions. The simple mathematical addition of the corrected performance of each turbine ignores the well-known fact that the steam turbine-generator output in a combined cycle plant is impacted by the gas turbine exhaust conditions, in particular the gas turbine exhaust flow and temperature. The purpose of this paper is to provide a method for the determination of “Combined Turbine Equipment Performance”, review the supporting theory, highlight the assumptions, and develop useful transfer functions for some commonly used combined cycle plant configurations, and bound the uncertainty associated with the methodology.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

“Combined Turbine Equipment Performance” represents the combined performance of the Gas Turbine-Generator(s) and the Steam Turbine-Generator(s), while disregarding or holding the performance of the remaining equipment in the Power Plant at its design levels. The lack of established industry standards and methods addressing the manner in which combined turbine equipment performance should be determined has invited confusion and has created opportunities for technical errors to go undetected. This paper presents a method and the supporting theory by which the corrected performance of the turbine-generators within a combined cycle plant can be combined to gauge their combined performance levels for either contractual compliance or for diagnostic purposes. The Combined Turbine Equipment Performance methodology provided in this paper, allows the performance engineer to easily separate the performance contribution of each turbine generator from the overall plant performance. As such, this information becomes a powerful diagnostic tool in circumstances where a reconciliation of overall plant performance is desired. Individual (gas or steam) turbine performance can be determined by conducting a test in accordance with the respective test code (ASME PTC 22 or PTC 6.2). However, each of these test codes corrects the measured equipment performance to fundamentally different reference conditions. Where the gas turbine-generator measured performance is corrected primarily to ambient reference conditions, the steam turbine-generator measured performance is corrected to steam flows and other steam reference conditions. The simple mathematical addition of the corrected performance of each turbine ignores the well-known fact that the steam turbine-generator output in a combined cycle plant is impacted by the gas turbine exhaust conditions, in particular the gas turbine exhaust flow and temperature. The purpose of this paper is to provide a method for the determination of “Combined Turbine Equipment Performance”, review the supporting theory, highlight the assumptions, and develop useful transfer functions for some commonly used combined cycle plant configurations, and bound the uncertainty associated with the methodology.

Key concepts: Steam turbine, Turbine, Combined cycle, Boiler (water heating), Steam-electric power station, Generator (circuit theory), Engineering, Automotive engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Combined Turbine Equipment Performance — Research Paper | ScholarLens