2016•SpineOpen access

Complications and Rates of Subsequent Lumbar Surgery Following Lumbar Total Disc Arthroplasty and Lumbar Fusion

Claire D. Eliasberg, Michael P. Kelly, Remi M. Ajiboye, Nelson F. SooHoo

Open full text 41 citations

Abstract

STUDY DESIGN: Retrospective analysis. OBJECTIVE: To examine complications and rates of subsequent surgery following lumbar spinal fusion (LF) and lumbar total disc arthroplasty (TDA) at up to 5-year follow-up. SUMMARY OF BACKGROUND DATA: LF is commonly used in the management of degenerative disc disease causing pain refractory to nonoperative management. Lumbar TDA was developed as an alternative to fusion with the theoretical advantage of reducing rates of adjacent segment pathology and reoperation. Most prior reports comparing these 2 interventions have come from industry-sponsored investigational device exemption trials and no large-scale administrative database comparisons exist. METHODS: The California Office of Statewide Health Planning and Development discharge database was queried for patients aged 18 to 65 years undergoing lumbar TDA and LF for degenerative disc disease from 2004 to 2010. Patient characteristics were collected, and rates of complications and readmission were identified. Rates of repeat lumbar surgery were calculated at 90-day and 1-, 3-, and 5-year follow-up intervals. RESULTS: A total of 52,877 patients met the inclusion criteria (LF = 50,462, TDA = 2415). Wound infections were more common following LF than TDA (1.03% vs. 0.25%, P < 0.001). Rates of subsequent lumbar surgery at 90-day and 1-year follow-up were lower with lumbar TDA than LF (90-day-TDA: 2.94% vs. LF: 4.01%, P = 0.007; 1-yr-TDA: 3.46% vs. LF: 4.78%, P = 0.009). However, there were no differences in rates of subsequent lumbar surgery between the 2 groups at 3-year and 5-year follow-up. CONCLUSION: Lumbar TDA was associated with fewer early reoperations, though beyond 1 year, rates of reoperation were similar. Lumbar TDA may be associated with fewer acute infections, though this may be approach related and unrelated to the device itself. LEVEL OF EVIDENCE: 3.

About this research paper

What this paper is about

STUDY DESIGN: Retrospective analysis. OBJECTIVE: To examine complications and rates of subsequent surgery following lumbar spinal fusion (LF) and lumbar total disc arthroplasty (TDA) at up to 5-year follow-up. SUMMARY OF BACKGROUND DATA: LF is commonly used in the management of degenerative disc disease causing pain refractory to nonoperative management. Lumbar TDA was developed as an alternative to fusion with the theoretical advantage of reducing rates of adjacent segment pathology and reoperation. Most prior reports comparing these 2 interventions have come from industry-sponsored investigational device exemption trials and no large-scale administrative database comparisons exist. METHODS: The California Office of Statewide Health Planning and Development discharge database was queried for patients aged 18 to 65 years undergoing lumbar TDA and LF for degenerative disc disease from 2004 to 2010. Patient characteristics were collected, and rates of complications and readmission were identified. Rates of repeat lumbar surgery were calculated at 90-day and 1-, 3-, and 5-year follow-up intervals. RESULTS: A total of 52,877 patients met the inclusion criteria (LF = 50,462, TDA = 2415). Wound infections were more common following LF than TDA (1.03% vs. 0.25%, P < 0.001). Rates of subsequent lumbar surgery at 90-day and 1-year follow-up were lower with lumbar TDA than LF (90-day-TDA: 2.94% vs. LF: 4.01%, P = 0.007; 1-yr-TDA: 3.46% vs. LF: 4.78%, P = 0.009). However, there were no differences in rates of subsequent lumbar surgery between the 2 groups at 3-year and 5-year follow-up. CONCLUSION: Lumbar TDA was associated with fewer early reoperations, though beyond 1 year, rates of reoperation were similar. Lumbar TDA may be associated with fewer acute infections, though this may be approach related and unrelated to the device itself. LEVEL OF EVIDENCE: 3.

Why it matters

OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

STUDY DESIGN: Retrospective analysis. OBJECTIVE: To examine complications and rates of subsequent surgery following lumbar spinal fusion (LF) and lumbar total disc arthroplasty (TDA) at up to 5-year follow-up. SUMMARY OF BACKGROUND DATA: LF is commonly used in the management of degenerative disc disease causing pain refractory to nonoperative management. Lumbar TDA was developed as an alternative to fusion with the theoretical advantage of reducing rates of adjacent segment pathology and reoperation. Most prior reports comparing these 2 interventions have come from industry-sponsored investigational device exemption trials and no large-scale administrative database comparisons exist. METHODS: The California Office of Statewide Health Planning and Development discharge database was queried for patients aged 18 to 65 years undergoing lumbar TDA and LF for degenerative disc disease from 2004 to 2010. Patient characteristics were collected, and rates of complications and readmission were identified. Rates of repeat lumbar surgery were calculated at 90-day and 1-, 3-, and 5-year follow-up intervals. RESULTS: A total of 52,877 patients met the inclusion criteria (LF = 50,462, TDA = 2415). Wound infections were more common following LF than TDA (1.03% vs. 0.25%, P < 0.001). Rates of subsequent lumbar surgery at 90-day and 1-year follow-up were lower with lumbar TDA than LF (90-day-TDA: 2.94% vs. LF: 4.01%, P = 0.007; 1-yr-TDA: 3.46% vs. LF: 4.78%, P = 0.009). However, there were no differences in rates of subsequent lumbar surgery between the 2 groups at 3-year and 5-year follow-up. CONCLUSION: Lumbar TDA was associated with fewer early reoperations, though beyond 1 year, rates of reoperation were similar. Lumbar TDA may be associated with fewer acute infections, though this may be approach related and unrelated to the device itself. LEVEL OF EVIDENCE: 3.

Key concepts: Medicine, Lumbar, Degenerative disc disease, Surgery, Lumbar disc disease, Low back pain, Arthroplasty, Spinal fusion

Related papers

Back to paper searchBrowse research topicsOriginal source
Complications and Rates of Subsequent Lumbar Surgery Following Lumbar Total Disc Arthroplasty and Lumbar Fusion — Research Paper | ScholarLens