2014•Clinical Chemistry and Laboratory Medicine (CCLM)Requires access

Harmonization protocols for thyroid stimulating hormone (TSH) immunoassays: different approaches based on the consensus mean value

Aldo Clerico, Andrea Ripoli, Gian Carlo Zucchelli, Mario Plebani

Open publisher page 34 citations

Abstract

The lack of interchangeable laboratory results and consensus in current practices has underpinned greater attention to standardization and harmonization projects. In the area of method standardization and harmonization, there is considerable debate about how best to achieve comparability of measurement for immunoassays, and in particular heterogeneous proteins. The term standardization should be used only when comparable results among measurement procedures are based on calibration traceability to the International System of Units (SI unit) using a reference measurement procedure (RMP). Recently, it has been promoted the harmonization of methods for many immunoassays, and in particular for thyreotropin (TSH), as accepted RMPs are not available. In a recent paper published in this journal, a group of well-recognized authors used a complex statistical approach in order to reduce variability between the results observed with the 14 TSH immunoassay methods tested in their study. Here we provide data demonstrating that data from an external quality assessment (EQA) study allow similar results to those obtained using the reported statistical approach.

About this research paper

What this paper is about

The lack of interchangeable laboratory results and consensus in current practices has underpinned greater attention to standardization and harmonization projects. In the area of method standardization and harmonization, there is considerable debate about how best to achieve comparability of measurement for immunoassays, and in particular heterogeneous proteins. The term standardization should be used only when comparable results among measurement procedures are based on calibration traceability to the International System of Units (SI unit) using a reference measurement procedure (RMP). Recently, it has been promoted the harmonization of methods for many immunoassays, and in particular for thyreotropin (TSH), as accepted RMPs are not available. In a recent paper published in this journal, a group of well-recognized authors used a complex statistical approach in order to reduce variability between the results observed with the 14 TSH immunoassay methods tested in their study. Here we provide data demonstrating that data from an external quality assessment (EQA) study allow similar results to those obtained using the reported statistical approach.

Why it matters

OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The lack of interchangeable laboratory results and consensus in current practices has underpinned greater attention to standardization and harmonization projects. In the area of method standardization and harmonization, there is considerable debate about how best to achieve comparability of measurement for immunoassays, and in particular heterogeneous proteins. The term standardization should be used only when comparable results among measurement procedures are based on calibration traceability to the International System of Units (SI unit) using a reference measurement procedure (RMP). Recently, it has been promoted the harmonization of methods for many immunoassays, and in particular for thyreotropin (TSH), as accepted RMPs are not available. In a recent paper published in this journal, a group of well-recognized authors used a complex statistical approach in order to reduce variability between the results observed with the 14 TSH immunoassay methods tested in their study. Here we provide data demonstrating that data from an external quality assessment (EQA) study allow similar results to those obtained using the reported statistical approach.

Key concepts: Harmonization, Standardization, Comparability, Traceability, External quality assessment, Computer science, Thyroid hormones, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Harmonization protocols for thyroid stimulating hormone (TSH) immunoassays: different approaches based on the consensus mean value — Research Paper | ScholarLens