1996Therapeutic Drug MonitoringRequires access

Vancomycin Serum Concentrations in Patients with Renal Dysfunction: A Comparison of Fluorescence Polarization Immunoassay and the Enzyme-Multiplied Immunoassay Technique

Howard J. Peckman, Robert E. Dupuis, William T. Sawyer, Kim L. R. Brouwer, Robert E. Cross

Open publisher page 14 citations

Abstract

A study was conducted to determine whether assay-specific quantitative differences exist in the determination of vancomycin serum concentrations obtained from patients with renal dysfunction. Vancomycin serum concentrations were obtained during the first week of therapy for each of three time intervals: 48-96 h, 96-144 h, and 144-192 h after administration of the first dose of vancomycin. Vancomycin serum concentrations were measured using the enzyme-multiplied immunoassay technique (EMIT) and fluorescence polarization immunoassay (FPIA). Twenty patients with an estimated creatinine clearance < 40 ml/min who were receiving intravenous vancomycin were evaluated. Hemodialysis was required in 16 of 20 patients. Fifty samples were included in the data analysis. The mean (+/-SD) serum concentrations obtained with EMIT and FPIA were 10.9 mg/L (+/-5.3) and 12.6 mg/L (+/-5.7), respectively (p = 0.13), and were not statistically different. A linear relationship was observed between EMIT and FPIA (EMIT = 0.89 x FPIA - 0.24; r2 = 0.93). No statistically significant differences were observed in the calculated pharmacokinetic parameters between methods. FPIA and EMIT are comparable methods in determining vancomycin serum concentrations within the first week of vancomycin therapy in patients with moderate to severe renal dysfunction.

About this research paper

What this paper is about

A study was conducted to determine whether assay-specific quantitative differences exist in the determination of vancomycin serum concentrations obtained from patients with renal dysfunction. Vancomycin serum concentrations were obtained during the first week of therapy for each of three time intervals: 48-96 h, 96-144 h, and 144-192 h after administration of the first dose of vancomycin. Vancomycin serum concentrations were measured using the enzyme-multiplied immunoassay technique (EMIT) and fluorescence polarization immunoassay (FPIA). Twenty patients with an estimated creatinine clearance < 40 ml/min who were receiving intravenous vancomycin were evaluated. Hemodialysis was required in 16 of 20 patients. Fifty samples were included in the data analysis. The mean (+/-SD) serum concentrations obtained with EMIT and FPIA were 10.9 mg/L (+/-5.3) and 12.6 mg/L (+/-5.7), respectively (p = 0.13), and were not statistically different. A linear relationship was observed between EMIT and FPIA (EMIT = 0.89 x FPIA - 0.24; r2 = 0.93). No statistically significant differences were observed in the calculated pharmacokinetic parameters between methods. FPIA and EMIT are comparable methods in determining vancomycin serum concentrations within the first week of vancomycin therapy in patients with moderate to severe renal dysfunction.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A study was conducted to determine whether assay-specific quantitative differences exist in the determination of vancomycin serum concentrations obtained from patients with renal dysfunction. Vancomycin serum concentrations were obtained during the first week of therapy for each of three time intervals: 48-96 h, 96-144 h, and 144-192 h after administration of the first dose of vancomycin. Vancomycin serum concentrations were measured using the enzyme-multiplied immunoassay technique (EMIT) and fluorescence polarization immunoassay (FPIA). Twenty patients with an estimated creatinine clearance < 40 ml/min who were receiving intravenous vancomycin were evaluated. Hemodialysis was required in 16 of 20 patients. Fifty samples were included in the data analysis. The mean (+/-SD) serum concentrations obtained with EMIT and FPIA were 10.9 mg/L (+/-5.3) and 12.6 mg/L (+/-5.7), respectively (p = 0.13), and were not statistically different. A linear relationship was observed between EMIT and FPIA (EMIT = 0.89 x FPIA - 0.24; r2 = 0.93). No statistically significant differences were observed in the calculated pharmacokinetic parameters between methods. FPIA and EMIT are comparable methods in determining vancomycin serum concentrations within the first week of vancomycin therapy in patients with moderate to severe renal dysfunction.

Key concepts: Immunoassay, Fluorescence polarization immunoassay, Medicine, Chromatography, Vancomycin, Chemistry, Immunology, Staphylococcus aureus

Related papers

Back to paper searchBrowse research topicsOriginal source
Vancomycin Serum Concentrations in Patients with Renal Dysfunction: A Comparison of Fluorescence Polarization Immunoassay and the Enzyme-Multiplied Immunoassay Technique — Research Paper | ScholarLens