Autologous total ossicular replacement prosthesis
Manu Malhotra, Saurabh Varshney, R Malhotra
Abstract
Manu Malhotra, Saurabh Varshney, R Malhotra
Abstract
OBJECTIVE: To develop an autologous total ossicular replacement prosthesis with sustainable hearing results. METHODS: The ears of 40 patients, who had chronic otitis media with absent suprastructure of the stapes and long process of the incus, were repaired using the autologous total ossicular replacement technique. Post-operative results were evaluated after 6 and 12 months on the basis of average pure tone air conduction and average air-bone gap measured at 0.5, 1, 2 and 3 kHz. RESULTS: Successful rehabilitation of pure tone average to 30 dB or less was achieved in 75 per cent of patients, and air-bone gap to 20 dB or less was attained in 82.5 per cent of patients. Overall mean improvement in air-bone gap was 23.9 ± 8.5 dB (p < 0.001). Mean improvements in air-bone gap were significantly greater (p < 0.05) in the tympanoplasty only group (27.3 ± 6.6 dB) and the intact canal wall tympanoplasty group (25.9 ± 6.3 dB) than in the canal wall down tympanoplasty group (16.3 ± 8.9 dB). CONCLUSION: This paper describes an autologous total ossicular replacement prosthesis that is biocompatible, stable, magnetic resonance imaging compatible and, above all, results in sustainable hearing improvement.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To develop an autologous total ossicular replacement prosthesis with sustainable hearing results. METHODS: The ears of 40 patients, who had chronic otitis media with absent suprastructure of the stapes and long process of the incus, were repaired using the autologous total ossicular replacement technique. Post-operative results were evaluated after 6 and 12 months on the basis of average pure tone air conduction and average air-bone gap measured at 0.5, 1, 2 and 3 kHz. RESULTS: Successful rehabilitation of pure tone average to 30 dB or less was achieved in 75 per cent of patients, and air-bone gap to 20 dB or less was attained in 82.5 per cent of patients. Overall mean improvement in air-bone gap was 23.9 ± 8.5 dB (p < 0.001). Mean improvements in air-bone gap were significantly greater (p < 0.05) in the tympanoplasty only group (27.3 ± 6.6 dB) and the intact canal wall tympanoplasty group (25.9 ± 6.3 dB) than in the canal wall down tympanoplasty group (16.3 ± 8.9 dB). CONCLUSION: This paper describes an autologous total ossicular replacement prosthesis that is biocompatible, stable, magnetic resonance imaging compatible and, above all, results in sustainable hearing improvement.
Key concepts: Incus, Tympanoplasty, Medicine, Stapes, Prosthesis, Bone conduction, Surgery, Dentistry