The impact of R50 on −100°C three-stage auto-cascade refrigeration system

Chunxia Hu, Yang Shi, Xiangge Zhao, Guanjun Liu

Open publisher page 3 citations

Abstract

In this paper, a -100°C three-stage auto-cascade refrigeration system is proposed and the experimental device is established. In order to determine the impact of R50 on the refrigeration cycle, the experiments are made by using mixed-refrigerants with R134a/R23/R14 and R134a/R23/R14/R50 containing the same quantity of R134a, R23 and R14 respectively in the same device. By analyzing and comparing the different effects of the two experiments, it is found that when R50 is added into the mixed-refrigerants, the evaporation temperature and the temperature after condensation at the second-stage and the third-stage partial condensers are lower, but the high pressure is increased. The higher the hige pressure is, the more power consumption is needed and more time is required to achieve the designed temperature. So it is harmful to the cycle performance of the three-stage auto-cascade refrigeration system when R50 is added into the mixed-refrigerants.

About this research paper

What this paper is about

In this paper, a -100°C three-stage auto-cascade refrigeration system is proposed and the experimental device is established. In order to determine the impact of R50 on the refrigeration cycle, the experiments are made by using mixed-refrigerants with R134a/R23/R14 and R134a/R23/R14/R50 containing the same quantity of R134a, R23 and R14 respectively in the same device. By analyzing and comparing the different effects of the two experiments, it is found that when R50 is added into the mixed-refrigerants, the evaporation temperature and the temperature after condensation at the second-stage and the third-stage partial condensers are lower, but the high pressure is increased. The higher the hige pressure is, the more power consumption is needed and more time is required to achieve the designed temperature. So it is harmful to the cycle performance of the three-stage auto-cascade refrigeration system when R50 is added into the mixed-refrigerants.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper, a -100°C three-stage auto-cascade refrigeration system is proposed and the experimental device is established. In order to determine the impact of R50 on the refrigeration cycle, the experiments are made by using mixed-refrigerants with R134a/R23/R14 and R134a/R23/R14/R50 containing the same quantity of R134a, R23 and R14 respectively in the same device. By analyzing and comparing the different effects of the two experiments, it is found that when R50 is added into the mixed-refrigerants, the evaporation temperature and the temperature after condensation at the second-stage and the third-stage partial condensers are lower, but the high pressure is increased. The higher the hige pressure is, the more power consumption is needed and more time is required to achieve the designed temperature. So it is harmful to the cycle performance of the three-stage auto-cascade refrigeration system when R50 is added into the mixed-refrigerants.

Key concepts: Refrigerant, Refrigeration, Cascade, Stage (stratigraphy), Condensation, Thermodynamics, Evaporation, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
The impact of R50 on −100°C three-stage auto-cascade refrigeration system — Research Paper | ScholarLens